Sensitivity comparison of control charts under MAD shift detector using the rank set sampling scheme

In this article, the sensitivity comparison of the standard Shewhart S-control chart is done with the MAD-control chart under the rank set sampling (RSS) scheme. The median absolute deviation (MAD) from the sample median is considered a robust estimator for the outlier's detection relative to the sample standard deviation (SD). Extensive simulations are conducted to evaluate the control charts' performance using both estimators under the RSS scheme for different sample sizes. The values for the out-of-control average run length (ARL1), standard deviation of run length (SDRL) and percentile points under different shifts are used as performance measures. On the basis of Monte Carlo simulations, it is revealed that as the shift gets large; control charts are equally effective to detect it while for small shifts, the suggested robust MAD-control chart performed well and better. A real-life dataset is analysed to support our findings from the simulation study for illustrative intents justified that the MAD robust estimator is a better outlier detector. [Received: 26 November 2022; Accepted: 11 August 2023]

Authors

Institutions

Publication Details

Journal
European J of Industrial Engineering
Published
2024-12-04
DOI
https://doi.org/10.1504/ejie.2025.143089
Primary Topic
Advanced Statistical Process Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity comparison of control charts under MAD shift detector using the rank set sampling scheme

Moustafa Omar Ahmed Abu Shawiesh, Nadia Saeed
European J of Industrial Engineering
Advanced Statistical Process Monitoring
article

Sensitivity comparison of control charts under MAD shift detector using the rank set sampling scheme

Moustafa Omar Ahmed Abu Shawiesh, Nadia Saeed
article en

Abstract

In this article, the sensitivity comparison of the standard Shewhart S-control chart is done with the MAD-control chart under the rank set sampling (RSS) scheme. The median absolute deviation (MAD) from the sample median is considered a robust estimator for the outlier's detection relative to the sample standard deviation (SD). Extensive simulations are conducted to evaluate the control charts' performance using both estimators under the RSS scheme for different sample sizes. The values for the out-of-control average run length (ARL1), standard deviation of run length (SDRL) and percentile points under different shifts are used as performance measures. On the basis of Monte Carlo simulations, it is revealed that as the shift gets large; control charts are equally effective to detect it while for small shifts, the suggested robust MAD-control chart performed well and better. A real-life dataset is analysed to support our findings from the simulation study for illustrative intents justified that the MAD robust estimator is a better outlier detector. [Received: 26 November 2022; Accepted: 11 August 2023]

European J of Industrial EngineeringVol. 19(1)
Hashemite University (JO), University of the Punjab (PK)
Openalex Percentile: Top 78%
Advanced Statistical Process Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensitivity comparison of control charts under MAD shift detector using the rank set sampling scheme — Moustafa Omar Ahmed Abu Shawiesh, Nadia Saeed · European J of Industrial Engineering (2024) | TGRS Research Map | TGRS