Self-Expandable Versus Balloon-Expandable Transcatheter Aortic Valve Replacement for Treatment of Patients With Small Aortic Annulus: An Updated Meta-Analysis of Reconstructed Individual Patient Data

Transcatheter aortic valve replacement has emerged as an effective alternative to surgery in selected patients with aortic stenosis. It needs to be made clear which type of valve has better results in patients with small aortic annulus. We searched PubMed, Scopus, Embase, Cochrane Library, and Web of Science, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. A total of 27 articles were included, including 10,378 patients [5989 in balloon-expanding valve (BEV) and 4389 in the self-expanding valve (SEV) groups] with small aortic annulus. Our meta-analysis demonstrated no significant difference between SEVs and BEVs for 1-year all-cause mortality. There was a statistically significant increased risk of permanent pacemaker implantation (PPI) within 30 days and ischemic stroke at 1 year with SEVs [risk ratio (RR) = 1.69, 95% confidence interval (CI) = 1.18-2.42, P < 0.01, and RR = 1.83, 95% CI = 1.03-3.26, P = 0.04, respectively]. Our meta-analysis showed that SEVs are favored over BEVs in terms of 1-year change from baseline in effective orifice area (mean difference = 0.45, 95% CI = 0.19-0.71, P < 0.01). Moreover, after 1-year follow-up, severe patient-prosthesis mismatch was significantly lower in the SEV group (RR = 0.24, 95% CI = 0.11-0.53, P < 0.01). In conclusion, SEVs were associated with better echocardiographic outcomes from baseline. Patients with SEVs were more likely to develop stroke and require PPI but were less likely to have patient-prosthesis mismatch. The benefit of a larger effective aortic valve area with SEVs has to be balanced against higher PPI and stroke rates.

Authors

Institutions

Publication Details

Journal
Cardiology in Review
Published
2024-12-04
DOI
https://doi.org/10.1097/crd.0000000000000818
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Expandable Versus Balloon-Expandable Transcatheter Aortic Valve Replacement for Treatment of Patients With Small Aortic Annulus: An Updated Meta-Analysis of Reconstructed Individual Patient Data

Mohammed Tarek Hasan, David H. Roberts, Mohamed Hamouda Elkasaby, Ahmed R. Gonnah et al.
1 citations
Cardiology in Review
Cardiac Valve Diseases and Treatments
0.40
article

Self-Expandable Versus Balloon-Expandable Transcatheter Aortic Valve Replacement for Treatment of Patients With Small Aortic Annulus: An Updated Meta-Analysis of Reconstructed Individual Patient Data

Mohammed Tarek Hasan, David H. Roberts, Mohamed Hamouda Elkasaby, Ahmed R. Gonnah, Hussam Al Hennawi, Obieda Altobaishat, Basma Badrawy Khalefa, Mazen Negmeldin Aly Yassin, M. A. Mansour, Mohamed Abdalla Rashed, Abdallah Bani-Salame
article en
1 citations

Abstract

Transcatheter aortic valve replacement has emerged as an effective alternative to surgery in selected patients with aortic stenosis. It needs to be made clear which type of valve has better results in patients with small aortic annulus. We searched PubMed, Scopus, Embase, Cochrane Library, and Web of Science, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. A total of 27 articles were included, including 10,378 patients [5989 in balloon-expanding valve (BEV) and 4389 in the self-expanding valve (SEV) groups] with small aortic annulus. Our meta-analysis demonstrated no significant difference between SEVs and BEVs for 1-year all-cause mortality. There was a statistically significant increased risk of permanent pacemaker implantation (PPI) within 30 days and ischemic stroke at 1 year with SEVs [risk ratio (RR) = 1.69, 95% confidence interval (CI) = 1.18-2.42, P < 0.01, and RR = 1.83, 95% CI = 1.03-3.26, P = 0.04, respectively]. Our meta-analysis showed that SEVs are favored over BEVs in terms of 1-year change from baseline in effective orifice area (mean difference = 0.45, 95% CI = 0.19-0.71, P < 0.01). Moreover, after 1-year follow-up, severe patient-prosthesis mismatch was significantly lower in the SEV group (RR = 0.24, 95% CI = 0.11-0.53, P < 0.01). In conclusion, SEVs were associated with better echocardiographic outcomes from baseline. Patients with SEVs were more likely to develop stroke and require PPI but were less likely to have patient-prosthesis mismatch. The benefit of a larger effective aortic valve area with SEVs has to be balanced against higher PPI and stroke rates.

Cardiology in Review
Ain Shams University (EG), Cairo University (EG), University of Liverpool (GB), Imperial College Healthcare NHS Trust (GB), Jordan University of Science and Technology (JO), Al-Azhar University (EG), Blackpool Victoria Hospital (GB), Jefferson Hospital (US), Menoufia University (EG)
Good health and well-being
Openalex Percentile: Top 30%
Cardiac Valve Diseases and Treatments
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.