Design of an ultrasonic flowmeter using a cow horn-shaped structure and secretary bird optimization algorithm-back propagation neural network algorithm

A novel dual-channel ultrasonic flowmeter based on the time-difference method is proposed, aiming at solving the measurement error due to the installation angle of the transducers and improving the measurement accuracy. The angle error is eliminated by optimizing the ultrasonic propagation path so that it is parallel to the fluid flow direction. The pipeline design is optimized to reduce the pressure loss to ensure high-precision measurements at different flow rates. In addition, in order to solve the measurement accuracy problem caused by the transducer position, the measurement results of the two channels are fused by Secretary Bird Optimization Algorithm-Back Propagation Neural network, which reduces the error of the measurements and improves the overall accuracy of the measurements. The results of system error analysis and uncertainty evaluation show that the calibrated flowmeter has a maximum relative error of 0.6% and a maximum repeatability of 0.7%, which proves its reliability and effectiveness in fluid measurement.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2024-12-01
DOI
https://doi.org/10.1063/5.0239329
Citations
1
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of an ultrasonic flowmeter using a cow horn-shaped structure and secretary bird optimization algorithm-back propagation neural network algorithm

Ji Hua Sun, Zhongliang Wang, Lide Fang, Yiqian Sun et al.
1 citations
Physics of Fluids
Flow Measurement and Analysis
0.27
article

Design of an ultrasonic flowmeter using a cow horn-shaped structure and secretary bird optimization algorithm-back propagation neural network algorithm

Ji Hua Sun, Zhongliang Wang, Lide Fang, Yiqian Sun, Mi Wang, Limin Su
article en
1 citations

Abstract

A novel dual-channel ultrasonic flowmeter based on the time-difference method is proposed, aiming at solving the measurement error due to the installation angle of the transducers and improving the measurement accuracy. The angle error is eliminated by optimizing the ultrasonic propagation path so that it is parallel to the fluid flow direction. The pipeline design is optimized to reduce the pressure loss to ensure high-precision measurements at different flow rates. In addition, in order to solve the measurement accuracy problem caused by the transducer position, the measurement results of the two channels are fused by Secretary Bird Optimization Algorithm-Back Propagation Neural network, which reduces the error of the measurements and improves the overall accuracy of the measurements. The results of system error analysis and uncertainty evaluation show that the calibrated flowmeter has a maximum relative error of 0.6% and a maximum repeatability of 0.7%, which proves its reliability and effectiveness in fluid measurement.

Physics of FluidsVol. 36(12)
Ministry of Education of the People's Republic of China (CN), Baoding University (CN), Hebei University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 47%
Flow Measurement and Analysis
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.