Cosine response characteristic and cosine error for spectral irradiance sensors

Accurate spectral irradiance measurement is very important in the field of Earth observation. In the ideal condition, the measurement of spectral irradiance is expected to follow the cosine law of angular response, but the cosine diffuser does not exhibit the ideal cosine response in the actual measurement, the cosine error will affect the measurement result of the instrument. In order to understand the effect of cosine diffuser on the performance of the irradiance senor, a spectral irradiance experimental measurement system was established. The cosine errors of three spectrometers were measured. Two different methods, the traditional and offsetting angle response normalization method, were used to analyze the experimental results, respectively. The experimental results showed that cosine response characteristic was affected by many factors such as diffuser material and size, the adaptability of different angle response normalization method was different. Three different sensors were involved in this experiment: HOC spectral irradiance sensor, EVO spectrometer, and Fieldspec Spectroradiometer. The results indicated that the traditional normalization method is more suitable for HOC and EVO spectral irradiance sensors, and the former presents good cosine characteristics, but the latter is obviously wavelength dependent by the influence of element reflection and diffraction. Compared with conventional normalization method, the Fieldspec Spectroradiometer showed good cosine response characteristics using the offset method. When θ is in the range of 0~60°, the cosine error of thissensor is reduced from 11% to 6%, and it is almost independent of wavelength change.

Authors

Institutions

Publication Details

Published
2024-12-04
DOI
https://doi.org/10.1117/12.3037114
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cosine response characteristic and cosine error for spectral irradiance sensors

Caihong Dai, L. Wang, Ling Li, Zhifeng Wu et al.
Calibration and Measurement Techniques
article

Cosine response characteristic and cosine error for spectral irradiance sensors

Caihong Dai, L. Wang, Ling Li, Zhifeng Wu, Yanfei Wang, Jiang Pan
article en

Abstract

Accurate spectral irradiance measurement is very important in the field of Earth observation. In the ideal condition, the measurement of spectral irradiance is expected to follow the cosine law of angular response, but the cosine diffuser does not exhibit the ideal cosine response in the actual measurement, the cosine error will affect the measurement result of the instrument. In order to understand the effect of cosine diffuser on the performance of the irradiance senor, a spectral irradiance experimental measurement system was established. The cosine errors of three spectrometers were measured. Two different methods, the traditional and offsetting angle response normalization method, were used to analyze the experimental results, respectively. The experimental results showed that cosine response characteristic was affected by many factors such as diffuser material and size, the adaptability of different angle response normalization method was different. Three different sensors were involved in this experiment: HOC spectral irradiance sensor, EVO spectrometer, and Fieldspec Spectroradiometer. The results indicated that the traditional normalization method is more suitable for HOC and EVO spectral irradiance sensors, and the former presents good cosine characteristics, but the latter is obviously wavelength dependent by the influence of element reflection and diffraction. Compared with conventional normalization method, the Fieldspec Spectroradiometer showed good cosine response characteristics using the offset method. When θ is in the range of 0~60°, the cosine error of thissensor is reduced from 11% to 6%, and it is almost independent of wavelength change.

China Jiliang University (CN)
Climate action
Openalex Percentile: Top 65%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Cosine response characteristic and cosine error for spectral irradiance sensors — Caihong Dai, L. Wang, et al. · (2024) | TGRS Research Map | TGRS