Validation of dosimetry programs (Olinda & IDAC) for evaluation of absorbed dose in 177LuPSMA therapy of metastatic castration-resistant prostate cancer (mCRPC) using Monte Carlo simulation
The absorbed dose of organs in the first treatment cycle remained below tolerable limits. However, cumulative absorbed doses should be considered for the administered activities in the next cycles of treatment. While Monte Carlo, IDAC, and OLINDA results were aligned for organ dose calculations, patient-specific dosimetry may be necessary due to anatomical and functional changes. Accurate dose estimation for undefined organs and metastatic regions using the spherical model is significantly influenced by tissue density, highlighting the value of CT imaging.
Authors
- Mehdi Momennezhad (ORCID: https://orcid.org/0000-0002-1509-0446)
- Shahrokh Nasseri
- Hossein Arabi (ORCID: https://orcid.org/0000-0001-6526-0960)
- Kamran Aryana (ORCID: https://orcid.org/0000-0003-2403-8903)
- Sirwan Maroufpour
- Zahra Fazeli
Institutions
- Mashhad University of Medical Sciences (IR)
- University Hospital of Geneva (CH)
- Imam Reza Hospital (IR)
Publication Details
- Journal
- EJNMMI Physics
- Published
- 2024-12-03
- DOI
- https://doi.org/10.1186/s40658-024-00691-7
- Citations
- 5
- Primary Topic
- Prostate Cancer Treatment and Research
- Type
- article
- Field-Weighted Citation Impact
- 2.09
Funders