Enhancing Estimation Accuracy of Prostate Cancer VMAT Planning: A Knowledge-based Approach Using Multiple Collimator Angles

Background/Aim: This study aimed to determine whether a knowledge-based planning model incorporating treatment plans with multiple collimator angles (Multi-coll. model) provides superior estimation accuracy and plan quality for a range of collimator angles compared with a typical institutional model (Inst. model). Materials and Methods: Five institutions using volumetric modulated arc therapy for prostate cancer participated in the study. The Inst. model comprised plans using a fixed collimator angle, whereas the Multi-coll. model registered plans using single arcs and collimator angles of 10°, 30°, 50°, and 70°. The coefficient of determination and mean squared error were calculated, and the estimation accuracy and dosimetric results for three validation cases at each institution were compared for each model. Dosimetric parameters included volumes receiving at least 20%, 50%, and 90% of the prescription dose (V<sub>20</sub>, V<sub>50</sub>, and V<sub>90</sub>, respectively) at each collimator angle. Results: The Multi-coll. model yielded a higher coefficient of determination and lower mean squared error than the Inst. model, although overfitting of data was a concern at two institutions. The mean absolute errors between estimated and calculated values were (Inst. model vs. Multi-coll. model): 4.41% vs. 2.60% (V<sub>20</sub>), 4.03% vs. 2.27% (V<sub>50</sub>), and 2.07% vs. 1.09% (V<sub>90</sub>) for the rectum; 3.48% vs. 3.42% (V<sub>20</sub>), 2.24% vs. 3.65% (V<sub>50</sub>), and 1.11% vs. 0.73% (V<sub>90</sub>) for the bladder. The Multi-coll. model exhibited a lower rectal and vesical V<sub>20</sub> than the Inst. model. Conclusion: The Multi-coll. model had a greater estimation accuracy and slightly higher plan quality than the Inst. model.

Authors

Institutions

Publication Details

Journal
Anticancer Research
Published
2024-12-01
DOI
https://doi.org/10.21873/anticanres.17358
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Estimation Accuracy of Prostate Cancer VMAT Planning: A Knowledge-based Approach Using Multiple Collimator Angles

Tatsuya Kamima, Yoshihiro Ueda, Yasuo Yoshioka, Jun-ichi Fukunaga et al.
Anticancer Research
Advanced Radiotherapy Techniques
article

Enhancing Estimation Accuracy of Prostate Cancer VMAT Planning: A Knowledge-based Approach Using Multiple Collimator Angles

Tatsuya Kamima, Yoshihiro Ueda, Yasuo Yoshioka, Jun-ichi Fukunaga, Yumiko Shimizu, Hajime Monzen
article en

Abstract

Background/Aim: This study aimed to determine whether a knowledge-based planning model incorporating treatment plans with multiple collimator angles (Multi-coll. model) provides superior estimation accuracy and plan quality for a range of collimator angles compared with a typical institutional model (Inst. model). Materials and Methods: Five institutions using volumetric modulated arc therapy for prostate cancer participated in the study. The Inst. model comprised plans using a fixed collimator angle, whereas the Multi-coll. model registered plans using single arcs and collimator angles of 10°, 30°, 50°, and 70°. The coefficient of determination and mean squared error were calculated, and the estimation accuracy and dosimetric results for three validation cases at each institution were compared for each model. Dosimetric parameters included volumes receiving at least 20%, 50%, and 90% of the prescription dose (V<sub>20</sub>, V<sub>50</sub>, and V<sub>90</sub>, respectively) at each collimator angle. Results: The Multi-coll. model yielded a higher coefficient of determination and lower mean squared error than the Inst. model, although overfitting of data was a concern at two institutions. The mean absolute errors between estimated and calculated values were (Inst. model vs. Multi-coll. model): 4.41% vs. 2.60% (V<sub>20</sub>), 4.03% vs. 2.27% (V<sub>50</sub>), and 2.07% vs. 1.09% (V<sub>90</sub>) for the rectum; 3.48% vs. 3.42% (V<sub>20</sub>), 2.24% vs. 3.65% (V<sub>50</sub>), and 1.11% vs. 0.73% (V<sub>90</sub>) for the bladder. The Multi-coll. model exhibited a lower rectal and vesical V<sub>20</sub> than the Inst. model. Conclusion: The Multi-coll. model had a greater estimation accuracy and slightly higher plan quality than the Inst. model.

Anticancer ResearchVol. 44(12)
University of Tsukuba (JP), Kyushu University Hospital (JP), Seirei Hamamatsu General Hospital (JP), Osaka International Cancer Institute (JP), Japanese Foundation For Cancer Research (JP), Kindai University (JP)
Openalex Percentile: Top 69%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.