Venus cloud catcher as a proof of concept aerosol collection instrument

We report on the proof-of-concept of a low-mass, low-power method for collecting micron-sized sulfuric acid aerosols in bulk from the atmosphere of Venus. The collection method uses four wired meshes in a sandwich structure with a deposition area of 225 cm<sup>2</sup>. It operates in two modes: passive and electrostatic. During passive operation, aerosols are gathered on the deposition surface by aerodynamic force. During electrostatic operation, a tungsten needle discharges a high voltage of - 10 kV at the front of the grounded mesh structure. The discharge ionizes aerosols and attracts them to the mesh by Coulomb forces, resulting in improved efficiency and tentative attraction of submicron aerosols. We describe the instrument construction and testing in the laboratory under controlled conditions with aerosols composed of 25%, 50%, 70%, 80%, 90% and 98%* concentration by volume of sulfuric acid, the rest water. We demonstrated the following: (i) both modes of operation can collect the entire range of sulfuric acid solutions; (ii) the collection efficiency increases steadily (from a few percent for water to over 40% for concentrated sulfuric acid) with the increased concentration of sulfuric acid solution in water in both modes; (iii) the relative improvement in the collection of the electrostatic mode decreases as the sulfuric acid concentration increases. We also demonstrated the operation of the instrument in the field, cloud particle collection on Mt. Washington, NH, and crater-rim fumaroles' particle collection on Kīlauea volcano, HI. The collection rate in the field is wind-speed dependent, and we observed collection rates around 0.1 ml[Formula: see text] in low wind environments (1-2 m[Formula: see text]), and around 1 ml[Formula: see text] in stronger wind (7-9 m[Formula: see text]).

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-12-03
DOI
https://doi.org/10.1038/s41598-024-80847-8
Primary Topic
Planetary Science and Exploration
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Venus cloud catcher as a proof of concept aerosol collection instrument

Sara Seager, Rachana Agrawal, M. Regina A. Moreno, Christopher E. Carr et al.
Scientific Reports
Planetary Science and Exploration
article

Venus cloud catcher as a proof of concept aerosol collection instrument

Sara Seager, Rachana Agrawal, M. Regina A. Moreno, Christopher E. Carr, Janusz J. Petkowski, Iaroslav Iakubivskyi, Snigdha Nellutla
article en

Abstract

We report on the proof-of-concept of a low-mass, low-power method for collecting micron-sized sulfuric acid aerosols in bulk from the atmosphere of Venus. The collection method uses four wired meshes in a sandwich structure with a deposition area of 225 cm<sup>2</sup>. It operates in two modes: passive and electrostatic. During passive operation, aerosols are gathered on the deposition surface by aerodynamic force. During electrostatic operation, a tungsten needle discharges a high voltage of - 10 kV at the front of the grounded mesh structure. The discharge ionizes aerosols and attracts them to the mesh by Coulomb forces, resulting in improved efficiency and tentative attraction of submicron aerosols. We describe the instrument construction and testing in the laboratory under controlled conditions with aerosols composed of 25%, 50%, 70%, 80%, 90% and 98%* concentration by volume of sulfuric acid, the rest water. We demonstrated the following: (i) both modes of operation can collect the entire range of sulfuric acid solutions; (ii) the collection efficiency increases steadily (from a few percent for water to over 40% for concentrated sulfuric acid) with the increased concentration of sulfuric acid solution in water in both modes; (iii) the relative improvement in the collection of the electrostatic mode decreases as the sulfuric acid concentration increases. We also demonstrated the operation of the instrument in the field, cloud particle collection on Mt. Washington, NH, and crater-rim fumaroles' particle collection on Kīlauea volcano, HI. The collection rate in the field is wind-speed dependent, and we observed collection rates around 0.1 ml[Formula: see text] in low wind environments (1-2 m[Formula: see text]), and around 1 ml[Formula: see text] in stronger wind (7-9 m[Formula: see text]).

Scientific ReportsVol. 14(1)
Wrocław University of Science and Technology (PL), Georgia Institute of Technology (US), Geotermia Mazowiecka (Poland) (PL), American Institute of Aeronautics and Astronautics (US), Massachusetts Institute of Technology (US), AGH University of Krakow (PL)
National Aeronautics and Space Administration, Eesti Teadusagentuur, Nuclear Safety and Security Commission, Science Mission Directorate
Climate action
Openalex Percentile: Top 84%
Planetary Science and Exploration
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.