Preliminary steps for fabrication of microfluidic systems for swine sperm sorting: Materials, perfusing systems and flow

The success rate of assisted reproductive techniques in the livestock production can be optimized by improving the quality of the semen sample by selecting only the good quality sperm from the ejaculate. Microfluidic technology has been studied for sperm sorting mainly in human ejaculates but has not been studied for boar sperm. Spermatozoa have been proven to be highly sensitive to different microplastics, but the potential toxic effects of the materials used to set up microfluidic systems have not been studied. The main goal of this study was to assess the possible toxic effect on boar sperm of materials commonly used for a microfluidic system and to evaluate the effect of different flow control systems (peristaltic pump, syringe pump and a microfluidic flow controller) at different flow rates (10 μl*min-1, 100 μl*min-1 and 1 ml*min-1) on sperm quality, as preliminary information for the development of a swine sperm sorting microfluidic system. Results showed no negative effect of the different materials at different concentrations. The control reached the highest curvilinear velocity compared to the peristaltic pump and the pressure-based flow control system. In the flow rates, 10 μm*min-1 showed the poorest results and no significant differences were observed between control and 1 mlmin-1 flow in any of the parameters. In conclusion, all materials that were studied for microfluidic fabrications were suitable for sperm sorting, any of the pumps would be suitable for sperm selection and 1 ml*min-1 flow rate would be the flow rate of choice for sperm pumping.

Authors

Institutions

Publication Details

Journal
Research in Veterinary Science
Published
2024-12-03
DOI
https://doi.org/10.1016/j.rvsc.2024.105488
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary steps for fabrication of microfluidic systems for swine sperm sorting: Materials, perfusing systems and flow

Clara Malo, Rosa Monge, Luis Serrano, Alodia Lacueva-Aparicio
Research in Veterinary Science
Microfluidic and Bio-sensing Technologies
article

Preliminary steps for fabrication of microfluidic systems for swine sperm sorting: Materials, perfusing systems and flow

Clara Malo, Rosa Monge, Luis Serrano, Alodia Lacueva-Aparicio
article en

Abstract

The success rate of assisted reproductive techniques in the livestock production can be optimized by improving the quality of the semen sample by selecting only the good quality sperm from the ejaculate. Microfluidic technology has been studied for sperm sorting mainly in human ejaculates but has not been studied for boar sperm. Spermatozoa have been proven to be highly sensitive to different microplastics, but the potential toxic effects of the materials used to set up microfluidic systems have not been studied. The main goal of this study was to assess the possible toxic effect on boar sperm of materials commonly used for a microfluidic system and to evaluate the effect of different flow control systems (peristaltic pump, syringe pump and a microfluidic flow controller) at different flow rates (10 μl*min-1, 100 μl*min-1 and 1 ml*min-1) on sperm quality, as preliminary information for the development of a swine sperm sorting microfluidic system. Results showed no negative effect of the different materials at different concentrations. The control reached the highest curvilinear velocity compared to the peristaltic pump and the pressure-based flow control system. In the flow rates, 10 μm*min-1 showed the poorest results and no significant differences were observed between control and 1 mlmin-1 flow in any of the parameters. In conclusion, all materials that were studied for microfluidic fabrications were suitable for sperm sorting, any of the pumps would be suitable for sperm selection and 1 ml*min-1 flow rate would be the flow rate of choice for sperm pumping.

Research in Veterinary ScienceVol. 183
Universidad de Zaragoza (ES), Instituto de Nanociencia y Materiales de Aragón (ES), Instituto de Investigación Sanitaria Aragón (ES), University of Castilla-La Mancha (ES)
European Commission, Universidad de Zaragoza
Openalex Percentile: Top 80%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.