Effect of Production and Application Parameters on Acoustic Performance of Wood Wool Cement Panels

Introduction: A wood-wool cement panel (WWCP) is wood wool combined with Portland cement mortar. This environmentally friendly acoustic material can be used as a thermal insulator and fire-resistance material with desired mechanical properties. This study aimed to determine the mechanism by which WWCP absorbs sound and the effect of production and application parameters on absorption Material and Methods: The samples were prepared from poplar wood wool and white Portland cement as a binder in two Cement Fiber Ratios (CFR), namely 2:0.7 and 2:0.95, with bulk densities of 400, 500, and 600 Kg/m3 and thicknesses of 2 and 4 cm. Three layers of backing: air, polyurethane foam, and glass wool were examined separately. Acoustic absorption coefficient was measured using an impedance tube based on ISO 10534-2. Results: The highest increase in the average absorption coefficient due to the increase in thickness was observed for the sample with a density of 400 kg/m3 and CFR = 2: 0.95, equal to 0.3. Increasing the bulk density to 500 kg/m3 for most samples and in the high-frequency range led to rising absorption efficiency. The optimal backing effect was due to the placement of 4 cm of polyurethane foam behind the sample, which in both thicknesses led to an absorption peak with an absorption coefficient higher than 0.95 at frequencies between 400 and 500 Hz. Selected samples showed that painting WWCPs led to a limited drop in absorption coefficients at high frequencies, comparing the before and after painting results with oil-based paints. Conclusion: Tuning the absorption frequencies of these absorbers can be achieved by altering factors such as the thickness or density. It has been demonstrated that the effects of thickness and bulk density on the sound absorption of WWCP are related to each other. Concerning the CFR values, increasing the density did not significantly affect absorption in the two frequency ranges

Authors

Institutions

Publication Details

Journal
Journal of Health and Safety at Work
Published
2024-12-03
DOI
https://doi.org/10.18502/jhsw.v14i2.17145
Citations
1
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Production and Application Parameters on Acoustic Performance of Wood Wool Cement Panels

Mohammad Reza Monazzam Esmaeelpour, Ali Jafari, Fardin Zandsalimi
1 citations
Journal of Health and Safety at Work
Wood Treatment and Properties
0.27
article

Effect of Production and Application Parameters on Acoustic Performance of Wood Wool Cement Panels

Mohammad Reza Monazzam Esmaeelpour, Ali Jafari, Fardin Zandsalimi
article en
1 citations

Abstract

Introduction: A wood-wool cement panel (WWCP) is wood wool combined with Portland cement mortar. This environmentally friendly acoustic material can be used as a thermal insulator and fire-resistance material with desired mechanical properties. This study aimed to determine the mechanism by which WWCP absorbs sound and the effect of production and application parameters on absorption Material and Methods: The samples were prepared from poplar wood wool and white Portland cement as a binder in two Cement Fiber Ratios (CFR), namely 2:0.7 and 2:0.95, with bulk densities of 400, 500, and 600 Kg/m3 and thicknesses of 2 and 4 cm. Three layers of backing: air, polyurethane foam, and glass wool were examined separately. Acoustic absorption coefficient was measured using an impedance tube based on ISO 10534-2. Results: The highest increase in the average absorption coefficient due to the increase in thickness was observed for the sample with a density of 400 kg/m3 and CFR = 2: 0.95, equal to 0.3. Increasing the bulk density to 500 kg/m3 for most samples and in the high-frequency range led to rising absorption efficiency. The optimal backing effect was due to the placement of 4 cm of polyurethane foam behind the sample, which in both thicknesses led to an absorption peak with an absorption coefficient higher than 0.95 at frequencies between 400 and 500 Hz. Selected samples showed that painting WWCPs led to a limited drop in absorption coefficients at high frequencies, comparing the before and after painting results with oil-based paints. Conclusion: Tuning the absorption frequencies of these absorbers can be achieved by altering factors such as the thickness or density. It has been demonstrated that the effects of thickness and bulk density on the sound absorption of WWCP are related to each other. Concerning the CFR values, increasing the density did not significantly affect absorption in the two frequency ranges

Journal of Health and Safety at Work
Kurdistan University of Medical Sciences (IR), Tehran University of Medical Sciences (IR)
Openalex Percentile: Top 41%
Wood Treatment and Properties
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.