Quantitative sizing of microplastics up to 20 µm using ICP-TOFMS

A fundamental study of four different sample introduction systems was carried out to evaluate the upper size limit of microplastics measured by inductively coupled plasma-time-of-flight-mass spectrometry (ICP-TOFMS). Three different, certified microplastic samples (PS, PMMA and PVC) within a size range of 3-20 µm in suspension were measured. In this study, no particles larger than 10 µm could be detected using pneumatic nebulization for sample introduction. However, we were able to extend the upper size limit to 20 µm by either using a falling-tube device or a vertical downwards-pointing ICP-TOFMS. Particle transport efficiencies could only be estimated and were within a range of 13% to 184%. The particle size was quantified by using dissolved citric acid (non-matrix matched) and agreed with reference values. The critical size values were 2.3 µm for PS, 2.4 µm for PMMA and 3.0 µm for PVC. Additionally, in the case of PVC, chlorine could also be detected and the critical size value was 3.9 µm based on the <sup>35</sup>Cl<sup>+</sup> ion signal.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Atomic Spectrometry
Published
2024-12-03
DOI
https://doi.org/10.1039/d4ja00323c
Citations
12
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
1.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative sizing of microplastics up to 20 µm using ICP-TOFMS

Detlef Günther, Sandro Fazzolari, Bodo Hattendorf
12 citations
Journal of Analytical Atomic Spectrometry
Microplastics and Plastic Pollution
1.60
article

Quantitative sizing of microplastics up to 20 µm using ICP-TOFMS

Detlef Günther, Sandro Fazzolari, Bodo Hattendorf
article en
12 citations

Abstract

A fundamental study of four different sample introduction systems was carried out to evaluate the upper size limit of microplastics measured by inductively coupled plasma-time-of-flight-mass spectrometry (ICP-TOFMS). Three different, certified microplastic samples (PS, PMMA and PVC) within a size range of 3-20 µm in suspension were measured. In this study, no particles larger than 10 µm could be detected using pneumatic nebulization for sample introduction. However, we were able to extend the upper size limit to 20 µm by either using a falling-tube device or a vertical downwards-pointing ICP-TOFMS. Particle transport efficiencies could only be estimated and were within a range of 13% to 184%. The particle size was quantified by using dissolved citric acid (non-matrix matched) and agreed with reference values. The critical size values were 2.3 µm for PS, 2.4 µm for PMMA and 3.0 µm for PVC. Additionally, in the case of PVC, chlorine could also be detected and the critical size value was 3.9 µm based on the <sup>35</sup>Cl<sup>+</sup> ion signal.

Journal of Analytical Atomic SpectrometryVol. 40(1)
ETH Zurich (CH)
National Science Foundation, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Openalex Percentile: Top 18%
Microplastics and Plastic Pollution
1.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.