Cerebrospinal Fluid Leak Prevention in Intradural Spine Surgery: A Long Series Analysis of Closure with Non-Penetrating Titanium Clips

<b>Background/Objectives</b>: Postoperative cerebrospinal fluid (CSF) fistulas remain a significant concern in spinal neurosurgery, particularly following dural closure. The incidence of dural tears during spinal surgery is estimated between 1.6% and 10%. While direct suturing remains the gold standard, it has a failure rate of 5-10%. Various materials and techniques have been used to enhance dural closure. This study aims to assess the effectiveness of non-penetrating titanium clips (AnastoClip<sup>®</sup>) for dural closure in intradural spinal lesion surgeries. <b>Methods</b>: A prospective analysis was conducted on 272 patients who were operated on for intradural spinal lesions from August 2017 to December 2023. Dural closure was performed using non-penetrating titanium clips with sealant, and, in select cases, autologous grafts. Postoperative care included early mobilization and routine MRI to assess outcomes. A comparative analysis was performed with a cohort of 81 patients treated with traditional sutures. <b>Results</b>: Among the 272 patients, postoperative CSF leaks occurred in 32 cases (11.76%), requiring various management approaches. Thirteen cases required surgical revision, while others resolved with external lumbar drainage or fluid aspiration. Compared to the suture group, which had a fistula rate of 23.46%, the titanium clip group had a significantly lower fistula rate. Logistic regression analysis did not find statistically significant associations between fistula risk and clinical factors. <b>Conclusions</b>: Non-penetrating titanium clips provide an effective alternative to sutures for dural closure, reducing CSF leak rates. They preserve dural integrity, reduce operative time, and avoid imaging artifacts, making them a viable advancement in spinal surgery with outcomes comparable to, or better than, traditional techniques.

Authors

Institutions

Publication Details

Journal
Brain Sciences
Published
2024-12-03
DOI
https://doi.org/10.3390/brainsci14121223
Citations
1
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cerebrospinal Fluid Leak Prevention in Intradural Spine Surgery: A Long Series Analysis of Closure with Non-Penetrating Titanium Clips

Ali Baram, Massimo Tomei, Maurizio Fornari, Alessandro Ortolina et al.
1 citations
Brain Sciences
Spine and Intervertebral Disc Pathology
0.42
article

Cerebrospinal Fluid Leak Prevention in Intradural Spine Surgery: A Long Series Analysis of Closure with Non-Penetrating Titanium Clips

Ali Baram, Massimo Tomei, Maurizio Fornari, Alessandro Ortolina, Generoso Farinaro, Carla Daniela Anania, Donato Creatura, Maria Cleofe Ubezio, Leonardo Anselmi
article en
1 citations

Abstract

<b>Background/Objectives</b>: Postoperative cerebrospinal fluid (CSF) fistulas remain a significant concern in spinal neurosurgery, particularly following dural closure. The incidence of dural tears during spinal surgery is estimated between 1.6% and 10%. While direct suturing remains the gold standard, it has a failure rate of 5-10%. Various materials and techniques have been used to enhance dural closure. This study aims to assess the effectiveness of non-penetrating titanium clips (AnastoClip<sup>®</sup>) for dural closure in intradural spinal lesion surgeries. <b>Methods</b>: A prospective analysis was conducted on 272 patients who were operated on for intradural spinal lesions from August 2017 to December 2023. Dural closure was performed using non-penetrating titanium clips with sealant, and, in select cases, autologous grafts. Postoperative care included early mobilization and routine MRI to assess outcomes. A comparative analysis was performed with a cohort of 81 patients treated with traditional sutures. <b>Results</b>: Among the 272 patients, postoperative CSF leaks occurred in 32 cases (11.76%), requiring various management approaches. Thirteen cases required surgical revision, while others resolved with external lumbar drainage or fluid aspiration. Compared to the suture group, which had a fistula rate of 23.46%, the titanium clip group had a significantly lower fistula rate. Logistic regression analysis did not find statistically significant associations between fistula risk and clinical factors. <b>Conclusions</b>: Non-penetrating titanium clips provide an effective alternative to sutures for dural closure, reducing CSF leak rates. They preserve dural integrity, reduce operative time, and avoid imaging artifacts, making them a viable advancement in spinal surgery with outcomes comparable to, or better than, traditional techniques.

Brain SciencesVol. 14(12)
Humanitas University (IT), IRCCS Humanitas Research Hospital (IT)
Openalex Percentile: Top 32%
Spine and Intervertebral Disc Pathology
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.