IMPACT OF SEISMIC ZONES ON THE STRUCTURAL DESIGN OF HIGHRISE BUILDINGS FOR RECTANGULAR AND C-SECTION

Earthquakes induce vibrations in structures, causing motion in horizontal and vertical directions, with horizontal shaking being predominant. Proper consideration of lateral loads due to earthquakes is essential for designing earthquake-resistant reinforced concrete (RC) structures, especially high-rise buildings. This study analysesthe behaviour of a G+15 multi-storied RC building with a consistent story height of 3 meters, subjected to earthquake loads, using response spectrum analysis as per IS 1893 (Part-1): 2016. The seismic performance is evaluated for four seismic zones (II, III, IV, and V) using the ETABS software. Key parameters analysed include bending moment, shear force, lateral displacement, story shear, and story drift. Comparative results highlight the effects of varying seismic zone factors. The findings contribute to understanding structural behaviour under seismic conditions and optimizing designs for enhanced safety and performance in earthquake-prone regions. Keywords: Earthquake-resistant design, Seismic analysis, Response spectrum analysis, Reinforced concrete (RC) buildings, Seismic zones, ETABS, IS 1893 (Part-1): 2016.

Authors

Publication Details

Journal
INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT
Published
2024-12-03
DOI
https://doi.org/10.55041/ijsrem39358
Primary Topic
Seismic and Structural Analysis of Tall Buildings
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IMPACT OF SEISMIC ZONES ON THE STRUCTURAL DESIGN OF HIGHRISE BUILDINGS FOR RECTANGULAR AND C-SECTION

Mrs Pitla Srividya, D Kalyani
INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT
Seismic and Structural Analysis of Tall Buildings
article

IMPACT OF SEISMIC ZONES ON THE STRUCTURAL DESIGN OF HIGHRISE BUILDINGS FOR RECTANGULAR AND C-SECTION

Mrs Pitla Srividya, D Kalyani
article en

Abstract

Earthquakes induce vibrations in structures, causing motion in horizontal and vertical directions, with horizontal shaking being predominant. Proper consideration of lateral loads due to earthquakes is essential for designing earthquake-resistant reinforced concrete (RC) structures, especially high-rise buildings. This study analysesthe behaviour of a G+15 multi-storied RC building with a consistent story height of 3 meters, subjected to earthquake loads, using response spectrum analysis as per IS 1893 (Part-1): 2016. The seismic performance is evaluated for four seismic zones (II, III, IV, and V) using the ETABS software. Key parameters analysed include bending moment, shear force, lateral displacement, story shear, and story drift. Comparative results highlight the effects of varying seismic zone factors. The findings contribute to understanding structural behaviour under seismic conditions and optimizing designs for enhanced safety and performance in earthquake-prone regions. Keywords: Earthquake-resistant design, Seismic analysis, Response spectrum analysis, Reinforced concrete (RC) buildings, Seismic zones, ETABS, IS 1893 (Part-1): 2016.

INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENTVol. 08(12)
Sustainable cities and communities
Openalex Percentile: Top 75%
Seismic and Structural Analysis of Tall Buildings
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.