Evaluation of reliability and radiation dose reduction in coronary artery calcium scoring by using a low tube current and low kilo-voltage peak with advanced modelled iterative reconstruction
The low current-low kVp protocol for CAC scoring has comparable reliability to the standard technique with significant radiation dose reduction. This extremely low-dose protocol may prove useful as an alternative to standard CAC scoring, particularly for screening in the low-to-intermediate risk population.
Authors
- Niraj Nirmal Pandey (ORCID: https://orcid.org/0000-0001-6786-8304)
- Debanjan Nandi (ORCID: https://orcid.org/0000-0002-8982-9821)
- Priya Jagia (ORCID: https://orcid.org/0000-0001-5605-8672)
- Ambuj Roy (ORCID: https://orcid.org/0000-0001-6418-4388)
Institutions
- All India Institute of Medical Sciences (IN)
Publication Details
- Journal
- Acta cardiologica. Supplementum
- Published
- 2024-12-03
- DOI
- https://doi.org/10.1080/00015385.2024.2436314
- Citations
- 3
- Primary Topic
- Cardiac Imaging and Diagnostics
- Type
- article
- Field-Weighted Citation Impact