Experimental and analytical study of guyed mast with variable cable tensions

Guyed masts are a key component of the telecommunications infrastructure in several countries. Due to their characteristics, these structures are particularly susceptible to dynamic loading originated from strong winds, causing several collapses in recent decades.These structural failures evidence the need to improve the computational models currently used in the design process. The design process is generally based on simplified computational models of the structure, assuming simplified characteristics of its geometry or constructive design values which generally differ from the real characteristics. In the present work, a comparison is made between the modal characteristics and the structural response obtained for two computational models of an existing tower. In the first case, an idealized model of the structure is used, while in the second case, an updated model based on a field study is used. The results obtained show that the modal displacements are the modal parameter most sensitive to structural variations, whereas the study of the structural response of the tower reveals that the updated model presents efforts up to 50% larger on the structural elements for the analyzed wind loads, due to its initial configuration influenced by the asymmetrical prestressing of the cables.

Authors

Institutions

Publication Details

Journal
Obras y proyectos
Published
2024-12-03
DOI
https://doi.org/10.21703/0718-2813.2024.36.3001
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and analytical study of guyed mast with variable cable tensions

Roberto de la C. Llerena, Vivian B. Elena, Patricia Martín, Bruno Clavelo
Obras y proyectos
Vibration and Dynamic Analysis
article

Experimental and analytical study of guyed mast with variable cable tensions

Roberto de la C. Llerena, Vivian B. Elena, Patricia Martín, Bruno Clavelo
article en

Abstract

Guyed masts are a key component of the telecommunications infrastructure in several countries. Due to their characteristics, these structures are particularly susceptible to dynamic loading originated from strong winds, causing several collapses in recent decades.These structural failures evidence the need to improve the computational models currently used in the design process. The design process is generally based on simplified computational models of the structure, assuming simplified characteristics of its geometry or constructive design values which generally differ from the real characteristics. In the present work, a comparison is made between the modal characteristics and the structural response obtained for two computational models of an existing tower. In the first case, an idealized model of the structure is used, while in the second case, an updated model based on a field study is used. The results obtained show that the modal displacements are the modal parameter most sensitive to structural variations, whereas the study of the structural response of the tower reveals that the updated model presents efforts up to 50% larger on the structural elements for the analyzed wind loads, due to its initial configuration influenced by the asymmetrical prestressing of the cables.

Obras y proyectos(36)
Polytechnic José Antonio Echeverría (CU)
Openalex Percentile: Top 74%
Vibration and Dynamic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.