A Hybrid Photoplethysmography (PPG) Sensor System Design for Heart Rate Monitoring

A photoplethysmography (PPG) sensor is a cost-effective and efficacious way of measuring health conditions such as heart rate, oxygen saturation, and respiration rate. In this work, we present a hybrid PPG sensor system working in a reflective mode with an optoelectronic module, i.e., the combination of an inorganic light-emitting diode (LED) and a circular-shaped organic photodetector (OPD) surrounding the LED for efficient light harvest followed by the proper driving circuit for accurate PPG signal acquisition. The performance of the hybrid sensor system was confirmed by the heart rate detection process from the PPG using fast Fourier transform analysis. The PPG signal obtained with a 50% LED duty cycle and 250 Hz sampling rate resulted in accurate heart rate monitoring with an acceptable range of error. The effects of the LED duty cycle and the LED luminous intensity were found to be crucial to the heart rate accuracy and to the power consumption, i.e., indispensable factors for the hybrid sensor.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-11-29
DOI
https://doi.org/10.3390/s24237634
Citations
8
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.48

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Hybrid Photoplethysmography (PPG) Sensor System Design for Heart Rate Monitoring

Muhamad Affiq Bin Misran, Hiroshi Fujimoto, Reiji Hattori, Farjana Akter Jhuma et al.
8 citations
Sensors
Non-Invasive Vital Sign Monitoring
1.48
article

A Hybrid Photoplethysmography (PPG) Sensor System Design for Heart Rate Monitoring

Muhamad Affiq Bin Misran, Hiroshi Fujimoto, Reiji Hattori, Farjana Akter Jhuma, Hin-Wai Mo, Kentaro Harada
article en
8 citations

Abstract

A photoplethysmography (PPG) sensor is a cost-effective and efficacious way of measuring health conditions such as heart rate, oxygen saturation, and respiration rate. In this work, we present a hybrid PPG sensor system working in a reflective mode with an optoelectronic module, i.e., the combination of an inorganic light-emitting diode (LED) and a circular-shaped organic photodetector (OPD) surrounding the LED for efficient light harvest followed by the proper driving circuit for accurate PPG signal acquisition. The performance of the hybrid sensor system was confirmed by the heart rate detection process from the PPG using fast Fourier transform analysis. The PPG signal obtained with a 50% LED duty cycle and 250 Hz sampling rate resulted in accurate heart rate monitoring with an acceptable range of error. The effects of the LED duty cycle and the LED luminous intensity were found to be crucial to the heart rate accuracy and to the power consumption, i.e., indispensable factors for the hybrid sensor.

SensorsVol. 24(23)
Kyushu University (JP), Solutions Inc. (Japan)
Ministry of Education, Culture, Sports, Science and Technology, Japan International Cooperation Agency
Affordable and clean energy
Openalex Percentile: Top 19%
Non-Invasive Vital Sign Monitoring
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.