Wearable System for Continuous Estimation of Transepidermal Water Loss

To maintain skin moisture, we need to maintain good stratum corneum barrier function, which prevents moisture evaporation from the inside of the skin. Transepidermal water loss (TEWL), the amount of water that evaporates from the skin, indicates the state of barrier function. The barrier function of facial skin is easily damaged in daily life, and the condition of the skin becomes worse without us noticing. We should constantly monitor TEWL to prevent worsening skin conditions. In this paper, we propose a wearable device that continuously measures TEWL. We estimate TEWL using machine learning from temperature and humidity values of water evaporation from the skin and parameters that affect TEWL, such as skin surface temperature and galvanic skin response. We experimented with the prototype device in a controlled environment. We confirmed that the prototype device could estimate TEWL accurately enough to judge the skin’s condition in stationary and conversational situations. Then, we experimented to verify the environmental conditions for estimating TEWL using the prototype device. The prototype device could estimate TEWL with sufficient precision in an office without airflow. However, we could not estimate TEWL in the office with airflow and outdoor.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-12-03
DOI
https://doi.org/10.3390/electronics13234779
Citations
4
Primary Topic
Intravenous Infusion Technology and Safety
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable System for Continuous Estimation of Transepidermal Water Loss

Tsutomu Terada, Natsumi Matsui, Masahiko Tsukamoto, Ayumi Ohnishi et al.
4 citations
Electronics
Intravenous Infusion Technology and Safety
0.74
article

Wearable System for Continuous Estimation of Transepidermal Water Loss

Tsutomu Terada, Natsumi Matsui, Masahiko Tsukamoto, Ayumi Ohnishi, Ayaka Uyama, Tetsuzo Sugino
article en
4 citations

Abstract

To maintain skin moisture, we need to maintain good stratum corneum barrier function, which prevents moisture evaporation from the inside of the skin. Transepidermal water loss (TEWL), the amount of water that evaporates from the skin, indicates the state of barrier function. The barrier function of facial skin is easily damaged in daily life, and the condition of the skin becomes worse without us noticing. We should constantly monitor TEWL to prevent worsening skin conditions. In this paper, we propose a wearable device that continuously measures TEWL. We estimate TEWL using machine learning from temperature and humidity values of water evaporation from the skin and parameters that affect TEWL, such as skin surface temperature and galvanic skin response. We experimented with the prototype device in a controlled environment. We confirmed that the prototype device could estimate TEWL accurately enough to judge the skin’s condition in stationary and conversational situations. Then, we experimented to verify the environmental conditions for estimating TEWL using the prototype device. The prototype device could estimate TEWL with sufficient precision in an office without airflow. However, we could not estimate TEWL in the office with airflow and outdoor.

ElectronicsVol. 13(23)
Kobe University (JP)
Japan Society for the Promotion of Science
Clean water and sanitation
Openalex Percentile: Top 31%
Intravenous Infusion Technology and Safety
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Wearable System for Continuous Estimation of Transepidermal Water Loss — Tsutomu Terada, Natsumi Matsui, et al. · Electronics (2024) | TGRS Research Map | TGRS