Uncertainty Evaluation of NDIR Spectrometer for Measurement od CO<sub>2</sub> Concentration in Air

This paper deals with measurement of carbon dioxide concentration in the air. To measure the concentration of carbon dioxide, we can choose from a wide range of measuring devices that use different measurement techniques. Evaluation of the measurement system was based on the non-dispersive infrared (NDIR) carbon dioxide spectrometer. I presented the setup of the measuring device and the solutions to eliminate obstacles which were encountered during the measurements. For the evaluation certified reference material and technical gases have been used. The measurements were performed in a range from 0 ppm to 9500 ppm. In final part, the contributions to standard uncertainty have been described, which is an essential part of any measurement. The most important contributions to measurement uncertainty have been listed, evaluated and finally stated as the total standard uncertainty of the measurement system.

Authors

Institutions

Publication Details

Published
2024-10-14
DOI
https://doi.org/10.1109/metrosea62823.2024.10765731
Citations
1
Primary Topic
Vehicle emissions and performance
Type
article
Field-Weighted Citation Impact
0.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty Evaluation of NDIR Spectrometer for Measurement od CO2 Concentration in Air

Gaber Begeš, Andraž Janežič
1 citations
Vehicle emissions and performance
0.20
article

Uncertainty Evaluation of NDIR Spectrometer for Measurement od CO2 Concentration in Air

Gaber Begeš, Andraž Janežič
article en
1 citations

Abstract

This paper deals with measurement of carbon dioxide concentration in the air. To measure the concentration of carbon dioxide, we can choose from a wide range of measuring devices that use different measurement techniques. Evaluation of the measurement system was based on the non-dispersive infrared (NDIR) carbon dioxide spectrometer. I presented the setup of the measuring device and the solutions to eliminate obstacles which were encountered during the measurements. For the evaluation certified reference material and technical gases have been used. The measurements were performed in a range from 0 ppm to 9500 ppm. In final part, the contributions to standard uncertainty have been described, which is an essential part of any measurement. The most important contributions to measurement uncertainty have been listed, evaluated and finally stated as the total standard uncertainty of the measurement system.

University of Ljubljana (SI)
Openalex Percentile: Top 48%
Vehicle emissions and performance
0.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.