An Equivalent Heat Source Calculation Model for HSER Under Overload Conditions

The temperature of hermetically sealed electromagnetic relay (HSER) continues to rise during opening and closing process of contacts under overload condition. Contact is one of the important components of small sealed electromagnetic relays, and its contact characteristics and heating characteristics are closely related to the reliability of the whole relay. During the operation of the relay, there is physical wear between the contacts, after the load is applied, there is also the problem of arc erosion, in the working conditions of overload, the problem of electrical ablation is more serious, which will lead to the deterioration of the contact surface, the contact resistance between the contacts increases, the contact heat increases, affecting the life and reliability of the relay. The DC relay overload test rig was built, the scanned topography of contact surfaces under different load levels was photographed, and the effects of overload on the physical and electrical properties of the contacts were analyzed. By studying the microscopic contact process between the contacts and the effect of surface roughness on the contact resistance, the probability density function of the surface roughness of the contacts is introduced into the mathematical formulation of the contact resistance, and the mathematical model of the contact resistance between the contacts related to the surface roughness is obtained. The contact depth and contact temperature rise of contacts with different surface roughness were simulated by finite element method. The contact system thermal characteristic test system was designed and constructed, and the relay overload temperature rise test was carried out to verify the validity of the calculation model by comparing with the measured results.

Authors

Institutions

Publication Details

Published
2024-10-06
DOI
https://doi.org/10.1109/holm56222.2024.10768680
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Equivalent Heat Source Calculation Model for HSER Under Overload Conditions

Jiaxin You, Huimin Liang, Bo Li, Shi Libing et al.
Superconducting Materials and Applications
article

An Equivalent Heat Source Calculation Model for HSER Under Overload Conditions

Jiaxin You, Huimin Liang, Bo Li, Shi Libing, Zhu Yuelin, Wang Aobo
article en

Abstract

The temperature of hermetically sealed electromagnetic relay (HSER) continues to rise during opening and closing process of contacts under overload condition. Contact is one of the important components of small sealed electromagnetic relays, and its contact characteristics and heating characteristics are closely related to the reliability of the whole relay. During the operation of the relay, there is physical wear between the contacts, after the load is applied, there is also the problem of arc erosion, in the working conditions of overload, the problem of electrical ablation is more serious, which will lead to the deterioration of the contact surface, the contact resistance between the contacts increases, the contact heat increases, affecting the life and reliability of the relay. The DC relay overload test rig was built, the scanned topography of contact surfaces under different load levels was photographed, and the effects of overload on the physical and electrical properties of the contacts were analyzed. By studying the microscopic contact process between the contacts and the effect of surface roughness on the contact resistance, the probability density function of the surface roughness of the contacts is introduced into the mathematical formulation of the contact resistance, and the mathematical model of the contact resistance between the contacts related to the surface roughness is obtained. The contact depth and contact temperature rise of contacts with different surface roughness were simulated by finite element method. The contact system thermal characteristic test system was designed and constructed, and the relay overload temperature rise test was carried out to verify the validity of the calculation model by comparing with the measured results.

Harbin Institute of Technology (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 80%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Equivalent Heat Source Calculation Model for HSER Under Overload Conditions — Jiaxin You, Huimin Liang, et al. · (2024) | TGRS Research Map | TGRS