Harmonic Source Modeling of AC Electric Arc Furnace Based on Mechanism-data Serial Drive
The paper proposed a harmonic source model for AC electric arc furnaces (EAF) based on mechanism-data serial drive. Firstly, a steady-state model of EAF based on energy empirical formulas was established, and an asymmetric nonlinear resistance Chua's circuit was used as a modulation signal to simulate the chaotic mechanism inside the EAF, thus establishing a practical simulation model of the EAF. Based on measured data, the empirical parameters of the simulation model can be obtained, which in turn a large amount of harmonic simulation data can be acquired. Finally, an EAF harmonic source model was established by mechanism-data serial drive. The results show that the harmonic source model based on mechanism-data serial drive has good accuracy, which can provide reference and foundation for studying the harmonic emission level of AC electric arc furnaces.
Authors
- Hongkun Chen (ORCID: https://orcid.org/0000-0003-3173-6953)
- Yuanwei Yang (ORCID: https://orcid.org/0000-0002-4221-4563)
- Yufeng Jiang (ORCID: https://orcid.org/0000-0002-1405-7513)
- Yong Mei
- Aoyu Lei
- Jiaqi Wang (ORCID: https://orcid.org/0009-0008-7293-3156)
Institutions
- Wuhan University (CN)
- China Southern Power Grid (China) (CN)
Publication Details
- Published
- 2024-10-15
- DOI
- https://doi.org/10.1109/ichqp61174.2024.10768764
- Primary Topic
- Advanced Algorithms and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- China Southern Power Grid