On the Problematic of Serial Arc Fault Detection in Aircraft Under the Presence of Switching Devices

HVDC serial arc fault detection is currently one of the main concerns in aeronautics due to the increase in power levels expected for more-electric aircraft and hybrid propulsion; hence, the demand for a reliable and robust system for arc faults detection. However, the switching of different equipment during normal operation, may lead to falsely identifying these electric signatures as faults. This false tripping is a problem since its consequence is to switch-off the current that may affect critical loads. To address this problem, two solutions are possible: (i) inhibit the detection device during the opening/closing time of contactors or (ii) consider the opening/closing signatures as a normal behaviour of the circuit. This work evaluates the consequences of these two approaches by understanding how an arc fault can affect the electrical system: (i) in case there is no protection device during inhibition time or (ii) if the detection device takes into account all behaviours coming from different contactors. The destructive energy capacity of a potential arc fault was also estimated by measuring the contactor's opening/closing time in a laboratory experimental setup in order to assess the impact of its inhibition.

Authors

Institutions

Publication Details

Published
2024-10-06
DOI
https://doi.org/10.1109/holm56222.2024.10768458
Primary Topic
Risk and Safety Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the Problematic of Serial Arc Fault Detection in Aircraft Under the Presence of Switching Devices

Thierry Ditchi, Thierry Lebey, Yacine Oussar, Cyril Van de Steen et al.
Risk and Safety Analysis
article

On the Problematic of Serial Arc Fault Detection in Aircraft Under the Presence of Switching Devices

Thierry Ditchi, Thierry Lebey, Yacine Oussar, Cyril Van de Steen, Raul Carreira Rufato, Malyk Benmouffok
article en

Abstract

HVDC serial arc fault detection is currently one of the main concerns in aeronautics due to the increase in power levels expected for more-electric aircraft and hybrid propulsion; hence, the demand for a reliable and robust system for arc faults detection. However, the switching of different equipment during normal operation, may lead to falsely identifying these electric signatures as faults. This false tripping is a problem since its consequence is to switch-off the current that may affect critical loads. To address this problem, two solutions are possible: (i) inhibit the detection device during the opening/closing time of contactors or (ii) consider the opening/closing signatures as a normal behaviour of the circuit. This work evaluates the consequences of these two approaches by understanding how an arc fault can affect the electrical system: (i) in case there is no protection device during inhibition time or (ii) if the detection device takes into account all behaviours coming from different contactors. The destructive energy capacity of a potential arc fault was also estimated by measuring the contactor's opening/closing time in a laboratory experimental setup in order to assess the impact of its inhibition.

Centre National de la Recherche Scientifique (FR), Sorbonne Université (FR), IRT M2P (FR), Safran (France) (FR), IRT Saint Exupéry, ESPCI Paris (FR)
Openalex Percentile: Top 78%
Risk and Safety Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On the Problematic of Serial Arc Fault Detection in Aircraft Under the Presence of Switching Devices — Thierry Ditchi, Thierry Lebey, et al. · (2024) | TGRS Research Map | TGRS