Intermittent Arc Fault Section Location in Power Distribution Network Using Distributed HFCT Disturbance Monitoring

Intermittent arcs in the distribution network have a random distribution and prominent high-frequency characteristics. This paper proposes innovatively using High-Frequency Current Transformers (HFCTs) installed distributedly in cable networks to capture waveforms of intermittent arc faults. Through real HFCT experiments, the paper validates the effectiveness of HFCT in capturing high-frequency arc waveforms. Building upon experimental sampling results, the paper employs empirical mode decomposition (EMD) and the Teager energy operator (TEO) to decompose the filtered arc transient disturbance waveforms through HFCT, and proposes a method for arc section location based on transient disturbance energy and phase comparison. The method is tested on an IEEE 34-node distribution network, demonstrating that the proposed method can effectively localize intermittent arc faults in underground distribution networks. This paper significantly extends the utility value of HFCTs, providing new insights and monitoring schemes for early fault detection in underground cable networks.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/ichqp61174.2024.10768721
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intermittent Arc Fault Section Location in Power Distribution Network Using Distributed HFCT Disturbance Monitoring

Xinyue Zhou, Lulu Li, Yi Zhong, Kongyao Wu
Electrical Fault Detection and Protection
article

Intermittent Arc Fault Section Location in Power Distribution Network Using Distributed HFCT Disturbance Monitoring

Xinyue Zhou, Lulu Li, Yi Zhong, Kongyao Wu
article en

Abstract

Intermittent arcs in the distribution network have a random distribution and prominent high-frequency characteristics. This paper proposes innovatively using High-Frequency Current Transformers (HFCTs) installed distributedly in cable networks to capture waveforms of intermittent arc faults. Through real HFCT experiments, the paper validates the effectiveness of HFCT in capturing high-frequency arc waveforms. Building upon experimental sampling results, the paper employs empirical mode decomposition (EMD) and the Teager energy operator (TEO) to decompose the filtered arc transient disturbance waveforms through HFCT, and proposes a method for arc section location based on transient disturbance energy and phase comparison. The method is tested on an IEEE 34-node distribution network, demonstrating that the proposed method can effectively localize intermittent arc faults in underground distribution networks. This paper significantly extends the utility value of HFCTs, providing new insights and monitoring schemes for early fault detection in underground cable networks.

Kunming University of Science and Technology (CN)
National Natural Science Foundation of China
Climate action
Openalex Percentile: Top 81%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.