Harmonic Performance Differences under Non-ideal Grid between Grid-Following and Grid-Forming Converters

Renewable energy generation devices need power electronic converters to be connected to the grid. Presently, the grid-following converter (GFL) and the grid-forming converter (GFM) are used in the electric power system for grid-connection control. As renewable energy progresses, power electronics play a growing role in power systems, leading to increased complexity in harmonic generation. The sinusoidal pulse width modulation (SPWM) and dead time can lead to the output of converter harmonics. Meanwhile, the grid voltage background harmonics also respond to the converter harmonics. Given the structural differences between GFL and GFM, there are differences in their harmonic outputs and responses. In this paper, the differences in the effects of control parameters, dead time, and background harmonics on the grid-connected current harmonics of GFL and GFM are analyzed. Finally, through a data-driven analysis, the simulation results validate the proposed harmonic performance differences between GFL and GFM.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/ichqp61174.2024.10768716
Citations
1
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic Performance Differences under Non-ideal Grid between Grid-Following and Grid-Forming Converters

Y. M. Lai, Yuanyuan Sun, Pengbo Shan, Yahui Li et al.
1 citations
Microgrid Control and Optimization
0.33
article

Harmonic Performance Differences under Non-ideal Grid between Grid-Following and Grid-Forming Converters

Y. M. Lai, Yuanyuan Sun, Pengbo Shan, Yahui Li, Lisheng Li, Yang Liu
article en
1 citations

Abstract

Renewable energy generation devices need power electronic converters to be connected to the grid. Presently, the grid-following converter (GFL) and the grid-forming converter (GFM) are used in the electric power system for grid-connection control. As renewable energy progresses, power electronics play a growing role in power systems, leading to increased complexity in harmonic generation. The sinusoidal pulse width modulation (SPWM) and dead time can lead to the output of converter harmonics. Meanwhile, the grid voltage background harmonics also respond to the converter harmonics. Given the structural differences between GFL and GFM, there are differences in their harmonic outputs and responses. In this paper, the differences in the effects of control parameters, dead time, and background harmonics on the grid-connected current harmonics of GFL and GFM are analyzed. Finally, through a data-driven analysis, the simulation results validate the proposed harmonic performance differences between GFL and GFM.

Shandong University (CN)
State Grid Corporation of China
Affordable and clean energy
Openalex Percentile: Top 39%
Microgrid Control and Optimization
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.