Upstream and Downstream Localization of Voltage Sag Source Based on Downstream Equivalent Fault Distance

Voltage sags cause significant economic losses in people's daily lives, making it particularly important to pinpoint the location of the disturbance source to clarify the responsibilities of both upstream and downstream parties. Most current methods do not account for the presence of distributed generation (DG) on the user side, leading to less-than-ideal accuracy. This paper proposes a method for voltage sag source location based on downstream equivalent fault distance, which can achieve upstream and downstream localization of voltage sag source in distribution networks with DG. The method first involves identifying the equivalent parameters of the system's three-sequence network, then calculating the equivalent fault distance based on the identified fault type, and finally determining the relative position of the disturbance source based on the equivalent fault distance. Testing and analysis using the improved IEEE 33 system demonstrated high localization accuracy, validating the effectiveness of the method.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/ichqp61174.2024.10768845
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Upstream and Downstream Localization of Voltage Sag Source Based on Downstream Equivalent Fault Distance

Qingwei Meng, Yue Hou, Le Yang
Power Systems Fault Detection
article

Upstream and Downstream Localization of Voltage Sag Source Based on Downstream Equivalent Fault Distance

Qingwei Meng, Yue Hou, Le Yang
article en

Abstract

Voltage sags cause significant economic losses in people's daily lives, making it particularly important to pinpoint the location of the disturbance source to clarify the responsibilities of both upstream and downstream parties. Most current methods do not account for the presence of distributed generation (DG) on the user side, leading to less-than-ideal accuracy. This paper proposes a method for voltage sag source location based on downstream equivalent fault distance, which can achieve upstream and downstream localization of voltage sag source in distribution networks with DG. The method first involves identifying the equivalent parameters of the system's three-sequence network, then calculating the equivalent fault distance based on the identified fault type, and finally determining the relative position of the disturbance source based on the equivalent fault distance. Testing and analysis using the improved IEEE 33 system demonstrated high localization accuracy, validating the effectiveness of the method.

State Grid Corporation of China (China) (CN), China University of Petroleum, East China (CN)
State Grid Shandong Electric Power Company
Climate action
Openalex Percentile: Top 74%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.