Analysis and Suppression of Circulating Current in Multiparalleled APFs with Grid Current Detected

Typically, to cope with the harmonic pollution, active power filters (APFs) are installed in power system. And they will be connected in parallel when meeting higher compensation demand in industrial applications. However, the circulating current emerges in the multiparalleled APFs with grid current detected. It will induce the DC voltage oscillation of multiparalleled APFs and eventually lead to the system shutdown. Therefore, in this article, the underlying mechanism of circulating current is analyzed, and its main frequency region is determined. It is demonstrated that the circulating current originates from the grid current feedback control and undamped circulating current path among multiparalleled APFs. To suppress the circulating current, this article proposes a virtual resistor method incorporated in the basic control, which emulates a resistor connected with the filter inductor in series. In this way, the circulating current path can be damped, which further eliminates the circulating current. Finally, simulations are conducted to verify the correctness of mechanism analysis and effectiveness of proposed virtual resistor method.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/ichqp61174.2024.10768828
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Suppression of Circulating Current in Multiparalleled APFs with Grid Current Detected

Zhenxiong Wang, Fang Zhuo, Hao Yi, Xin Jiang et al.
Advanced Fiber Optic Sensors
article

Analysis and Suppression of Circulating Current in Multiparalleled APFs with Grid Current Detected

Zhenxiong Wang, Fang Zhuo, Hao Yi, Xin Jiang, Zhilong Zhang, Yuguo Li
article en

Abstract

Typically, to cope with the harmonic pollution, active power filters (APFs) are installed in power system. And they will be connected in parallel when meeting higher compensation demand in industrial applications. However, the circulating current emerges in the multiparalleled APFs with grid current detected. It will induce the DC voltage oscillation of multiparalleled APFs and eventually lead to the system shutdown. Therefore, in this article, the underlying mechanism of circulating current is analyzed, and its main frequency region is determined. It is demonstrated that the circulating current originates from the grid current feedback control and undamped circulating current path among multiparalleled APFs. To suppress the circulating current, this article proposes a virtual resistor method incorporated in the basic control, which emulates a resistor connected with the filter inductor in series. In this way, the circulating current path can be damped, which further eliminates the circulating current. Finally, simulations are conducted to verify the correctness of mechanism analysis and effectiveness of proposed virtual resistor method.

State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 81%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.