Assessment and Treatment of Voltage Sag Based on Electric-Process PIT

Based on the strong correlation between petrochemical enterprises and the typical process parameters, an evaluation method combining traditional voltage tolerance curve with process immunity time based on process parameters was proposed. This method constructs a comprehensive evaluation index of safe operation of chemical plant after voltage sag, including electrical parameters and process parameters such as head and flow in the production process, which can realize sensitive identification of electrical parameter collapse and process index imbalance caused by voltage sag. Then, a circuit model is built according to the electrical parameters of a petrochemical enterprise, such as the circuit and the important sensitive load, and the typical sensitive load voltage sag is evaluated and treated. The results show that taking corresponding treatment measures based on the evaluation method of electric-process immune time curve can effectively enhance the stable operation ability of sensitive load and improve the power quality of petrochemical enterprises.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/ichqp61174.2024.10768758
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment and Treatment of Voltage Sag Based on Electric-Process PIT

Zhongjian Kang, Tianyu Yuan, Jiaxuan Liu
Fault Detection and Control Systems
article

Assessment and Treatment of Voltage Sag Based on Electric-Process PIT

Zhongjian Kang, Tianyu Yuan, Jiaxuan Liu
article en

Abstract

Based on the strong correlation between petrochemical enterprises and the typical process parameters, an evaluation method combining traditional voltage tolerance curve with process immunity time based on process parameters was proposed. This method constructs a comprehensive evaluation index of safe operation of chemical plant after voltage sag, including electrical parameters and process parameters such as head and flow in the production process, which can realize sensitive identification of electrical parameter collapse and process index imbalance caused by voltage sag. Then, a circuit model is built according to the electrical parameters of a petrochemical enterprise, such as the circuit and the important sensitive load, and the typical sensitive load voltage sag is evaluated and treated. The results show that taking corresponding treatment measures based on the evaluation method of electric-process immune time curve can effectively enhance the stable operation ability of sensitive load and improve the power quality of petrochemical enterprises.

Shanghai Electric (China) (CN), China University of Petroleum, East China (CN)
Clean water and sanitation
Openalex Percentile: Top 74%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment and Treatment of Voltage Sag Based on Electric-Process PIT — Zhongjian Kang, Tianyu Yuan, et al. · (2024) | TGRS Research Map | TGRS