Abnormal State Estimation of Shunt Capacitor Banks Based on Transient Power Disturbance Feature Extraction

Shunt capacitor banks are essential for reactive power compensation to ensure voltage stability and reduce system losses. Capacitor banks consist of multiple units with components in series and parallel. A small number of component failures will not immediately affect the safe operation of the capacitor bank. However, due to component breakdown, the capacitance voltage will be redistributed, which will have an impact on other devices. Practical operational experience shows that capacitors generate many transient disturbance signals when some components exhibit breakdown. Quantitative analysis of the transient disturbance signals can find capacitor anomalies, allowing the extraction of transient disturbance characteristics based on the Prony algorithm. The transient signals quantitatively estimate the phase and number of capacitors that break down to judge capacitor anomalies. In this paper, PSCAD/EMTDC provide a verification model. Thus, the theoretical analyses and correctness of the detection algorithm are verified.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/ichqp61174.2024.10768821
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abnormal State Estimation of Shunt Capacitor Banks Based on Transient Power Disturbance Feature Extraction

Long Zhang, Wen Xiao, Wenwen Zhou, Ming Ma et al.
Non-Destructive Testing Techniques
article

Abnormal State Estimation of Shunt Capacitor Banks Based on Transient Power Disturbance Feature Extraction

Long Zhang, Wen Xiao, Wenwen Zhou, Ming Ma, Wenhai Zhang, Yunping Zhong, Bi Hu
article en

Abstract

Shunt capacitor banks are essential for reactive power compensation to ensure voltage stability and reduce system losses. Capacitor banks consist of multiple units with components in series and parallel. A small number of component failures will not immediately affect the safe operation of the capacitor bank. However, due to component breakdown, the capacitance voltage will be redistributed, which will have an impact on other devices. Practical operational experience shows that capacitors generate many transient disturbance signals when some components exhibit breakdown. Quantitative analysis of the transient disturbance signals can find capacitor anomalies, allowing the extraction of transient disturbance characteristics based on the Prony algorithm. The transient signals quantitatively estimate the phase and number of capacitors that break down to judge capacitor anomalies. In this paper, PSCAD/EMTDC provide a verification model. Thus, the theoretical analyses and correctness of the detection algorithm are verified.

Sichuan University (CN), China Southern Power Grid (China) (CN)
China Southern Power Grid
Openalex Percentile: Top 78%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.