Survey of Harmonic Emission Limits Utilization Based on Measurements in Medium Voltage Networks

This paper studies the utilization of harmonic emission limits based on measurements in medium voltage networks in Germany. Disturbance measurements carried out over one week at around 100 different sites, including medium voltage customers and downstream low voltage networks, provide a credible basis for the analysis. The analysis focuses on the utilization of emission limits based on the harmonic currents of disturbing installations and their contribution to the harmonic voltage distortion at the point of connection. The results allow a robust assessment of the efficiency of the harmonic management and can identify possible inconsistencies in the electromagnetic compatibility coordination. The results highlight the importance of holistic analysis considering both harmonic currents and voltages for the measurement-based compliance assessment.

Authors

Institutions

Publication Details

Published
2024-10-15
DOI
https://doi.org/10.1109/ichqp61174.2024.10768837
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Survey of Harmonic Emission Limits Utilization Based on Measurements in Medium Voltage Networks

Jan Meyer, Morteza Pourarab, Victor Khokhlov
Power Line Communications and Noise
article

Survey of Harmonic Emission Limits Utilization Based on Measurements in Medium Voltage Networks

Jan Meyer, Morteza Pourarab, Victor Khokhlov
article en

Abstract

This paper studies the utilization of harmonic emission limits based on measurements in medium voltage networks in Germany. Disturbance measurements carried out over one week at around 100 different sites, including medium voltage customers and downstream low voltage networks, provide a credible basis for the analysis. The analysis focuses on the utilization of emission limits based on the harmonic currents of disturbing installations and their contribution to the harmonic voltage distortion at the point of connection. The results allow a robust assessment of the efficiency of the harmonic management and can identify possible inconsistencies in the electromagnetic compatibility coordination. The results highlight the importance of holistic analysis considering both harmonic currents and voltages for the measurement-based compliance assessment.

Technische Universität Dresden (DE)
Affordable and clean energy
Openalex Percentile: Top 81%
Power Line Communications and Noise
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.