DC-Link Split Capacitors Voltage Balancing Control of Hybrid Distribution Transformer

The dc-link split capacitors’ voltage unbalance will damage the normal operation of a hybrid distribution transformer (HDT). Based on the derived dynamic models related to the dc-link of HDT, this article reveals that the dc component of the load currents, modulating dc bias, sampling dc bias, and the capacitors parameters derivation are the main factors leading to the voltages unbalancing, and the active control of the grid currents’ zero-sequence component is a simple and key method to eliminating this unbalance. To address these, the split capacitors’ voltage balancing control strategy with proportional-integral (PI) controller is developed. To eliminate the static error and improve the system’s dynamic performance, the quasi-resonant regulators and load-neutral current feed-forward are added to the PI controller, thus formulating a novel controller. Simulation and experimental results validate the effectiveness of the proposed novel control strategy.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Electronics
Published
2024-12-03
DOI
https://doi.org/10.1109/tie.2024.3497331
Citations
4
Primary Topic
Sensorless Control of Electric Motors
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DC-Link Split Capacitors Voltage Balancing Control of Hybrid Distribution Transformer

Zihan Kong, Deliang Liang, Yanting Xue, Y. Liu
4 citations
IEEE Transactions on Industrial Electronics
Sensorless Control of Electric Motors
0.83
article

DC-Link Split Capacitors Voltage Balancing Control of Hybrid Distribution Transformer

Zihan Kong, Deliang Liang, Yanting Xue, Y. Liu
article en
4 citations

Abstract

The dc-link split capacitors’ voltage unbalance will damage the normal operation of a hybrid distribution transformer (HDT). Based on the derived dynamic models related to the dc-link of HDT, this article reveals that the dc component of the load currents, modulating dc bias, sampling dc bias, and the capacitors parameters derivation are the main factors leading to the voltages unbalancing, and the active control of the grid currents’ zero-sequence component is a simple and key method to eliminating this unbalance. To address these, the split capacitors’ voltage balancing control strategy with proportional-integral (PI) controller is developed. To eliminate the static error and improve the system’s dynamic performance, the quasi-resonant regulators and load-neutral current feed-forward are added to the PI controller, thus formulating a novel controller. Simulation and experimental results validate the effectiveness of the proposed novel control strategy.

IEEE Transactions on Industrial ElectronicsVol. 72(6)
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 26%
Sensorless Control of Electric Motors
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

DC-Link Split Capacitors Voltage Balancing Control of Hybrid Distribution Transformer — Zihan Kong, Deliang Liang, et al. · IEEE Transactions on Industrial Electronics (2024) | TGRS Research Map | TGRS