Retrograde evoked compound action potentials as an alternative for close-loop spinal cord stimulation

Evoked compound action potential (ECAP) is an important parameter in close-loop spinal cord stimulation (SCS). The recording electrode is typically positioned proximal to the stimulation electrode to capture the antegrade ECAP signals generated by ascending fibers. However, relatively little research has been conducted on retrograde ECAPs. This study investigated retrograde ECAPs using custom-made epidural electrodes in 11 adult male Sprague-Dawley rats. Results show that the average motor threshold (MT) and ECAP threshold (ECAPT) for 11 anesthetized rats were 218.18 ± 69.54 μA and 107.27 ± 27.96 μA, respectively. The ECAP amplitudes increased with increasement of the stimulation current and pulse width (PW), and were larger in awake rats than in anesthetized rats. Additionally, aside from ECAPs recorded by a commercial electrophysiological recorder, ECAPs were also recorded by a custom-made amplifier for the purpose of future long-term implantation, but the custom-made amplifier showed lower signal to noise ratio than the commercial amplifier. In conclusion, this study illustrates that retrograde ECAP may also be considered as a feedback signal for close-loop SCS and more sophisticated ECAP recording circuits are needed to form a close-loop system.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-12-03
DOI
https://doi.org/10.1038/s41598-024-81775-3
Citations
1
Primary Topic
Pain Management and Treatment
Type
article
Field-Weighted Citation Impact
0.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retrograde evoked compound action potentials as an alternative for close-loop spinal cord stimulation

Cheng Zhang, Nianshuang Wu, Xiaolin Huo, Guanghao Zhang et al.
1 citations
Scientific Reports
Pain Management and Treatment
0.64
article

Retrograde evoked compound action potentials as an alternative for close-loop spinal cord stimulation

Cheng Zhang, Nianshuang Wu, Xiaolin Huo, Guanghao Zhang, Zhen Wu, Jinzhu Bai, Changzhe Wu
article en
1 citations

Abstract

Evoked compound action potential (ECAP) is an important parameter in close-loop spinal cord stimulation (SCS). The recording electrode is typically positioned proximal to the stimulation electrode to capture the antegrade ECAP signals generated by ascending fibers. However, relatively little research has been conducted on retrograde ECAPs. This study investigated retrograde ECAPs using custom-made epidural electrodes in 11 adult male Sprague-Dawley rats. Results show that the average motor threshold (MT) and ECAP threshold (ECAPT) for 11 anesthetized rats were 218.18 ± 69.54 μA and 107.27 ± 27.96 μA, respectively. The ECAP amplitudes increased with increasement of the stimulation current and pulse width (PW), and were larger in awake rats than in anesthetized rats. Additionally, aside from ECAPs recorded by a commercial electrophysiological recorder, ECAPs were also recorded by a custom-made amplifier for the purpose of future long-term implantation, but the custom-made amplifier showed lower signal to noise ratio than the commercial amplifier. In conclusion, this study illustrates that retrograde ECAP may also be considered as a feedback signal for close-loop SCS and more sophisticated ECAP recording circuits are needed to form a close-loop system.

Scientific ReportsVol. 14(1)
Capital Medical University (CN), Chinese Academy of Sciences (CN), China Rehabilitation Research Center (CN), Institute of Electrical Engineering (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China
Zero hunger
Openalex Percentile: Top 25%
Pain Management and Treatment
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Retrograde evoked compound action potentials as an alternative for close-loop spinal cord stimulation — Cheng Zhang, Nianshuang Wu, et al. · Scientific Reports (2024) | TGRS Research Map | TGRS