Calculation and measurement of motor and converter losses according to IEC 61800-9-2 ED2

Abstract Calculated and measured motor and converter losses are compared using the example of a four-pole asynchronous motor with a rated output of 110 kW, operated on a standard converter. The determination of the motor losses using the polynomial approach to describe the motor losses in the field weakening range shows a clear deviation from the measurements. To calculate the converter losses, an equation for calculating the losses in DC link chokes was shown. The polynomial approach to describe the motor losses as a function of torque and speed can also be used for converters in the constant flux range. The semi-analytical model for calculating the converter losses shows satisfactory accuracy even when the motor is operated in the field weakening range.

Authors

Institutions

Publication Details

Journal
Forschung im Ingenieurwesen
Published
2024-12-01
DOI
https://doi.org/10.1007/s10010-024-00766-y
Citations
3
Primary Topic
Magnetic Properties and Applications
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculation and measurement of motor and converter losses according to IEC 61800-9-2 ED2

Andreas Kremser
3 citations
Forschung im Ingenieurwesen
Magnetic Properties and Applications
0.35
article

Calculation and measurement of motor and converter losses according to IEC 61800-9-2 ED2

Andreas Kremser
article en
3 citations

Abstract

Abstract Calculated and measured motor and converter losses are compared using the example of a four-pole asynchronous motor with a rated output of 110 kW, operated on a standard converter. The determination of the motor losses using the polynomial approach to describe the motor losses in the field weakening range shows a clear deviation from the measurements. To calculate the converter losses, an equation for calculating the losses in DC link chokes was shown. The polynomial approach to describe the motor losses as a function of torque and speed can also be used for converters in the constant flux range. The semi-analytical model for calculating the converter losses shows satisfactory accuracy even when the motor is operated in the field weakening range.

Forschung im IngenieurwesenVol. 88(1)
Georg Simon Ohm University of Applied Sciences Nuremberg (DE)
Affordable and clean energy
Openalex Percentile: Top 50%
Magnetic Properties and Applications
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.