Development and feasibility study of a piezoresistive pressure sensor-based automated system for monitoring and controlling gastric pressure in endoscopy

Maintaining precise intragastric pressure during gastrointestinal endoscopy is critical for patient safety and diagnostic accuracy, yet current methods relying on manual adjustments pose risks of improper insufflation. This study aimed to develop an automated gastric pressure control system for flexible endoscopy, addressing these challenges with a piezoresistive pressure sensor that can be integrated into a 7.3 mm diameter flexible endoscope. The system, incorporating air and suction pumps controlled by a microcontroller, was calibrated in an acrylic chamber and validated through comprehensive testing in both an endoscopy simulator and a porcine specimen. Testing scenarios included normal breathing, coughing, belching, and combined events, assessing accuracy, stability, and real-time pressure regulation under conditions mimicking physiological responses. Results demonstrated high accuracy (R<sup>2</sup> = 0.9999), minimal bias (0.23 mmHg), and strong agreement with reference standards, confirming effective pressure management. Simulated clinical scenarios in simulator and porcine specimen further showed the system's ability to maintain target pressure with minimal errors, indicating robustness under dynamic conditions. These findings suggest that the automated pressure control system significantly improves safety and procedural efficiency in endoscopy, with potential applicability to other minimally invasive procedures. Further animal model testing is recommended to validate the clinical performance under realistic physiological conditions.

Authors

Institutions

Publication Details

Journal
Medical & Biological Engineering & Computing
Published
2024-12-03
DOI
https://doi.org/10.1007/s11517-024-03254-1
Primary Topic
Abdominal Surgery and Complications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and feasibility study of a piezoresistive pressure sensor-based automated system for monitoring and controlling gastric pressure in endoscopy

Sungwan Kim, S.C. Lenny Koh
Medical & Biological Engineering & Computing
Abdominal Surgery and Complications
article

Development and feasibility study of a piezoresistive pressure sensor-based automated system for monitoring and controlling gastric pressure in endoscopy

Sungwan Kim, S.C. Lenny Koh
article en

Abstract

Maintaining precise intragastric pressure during gastrointestinal endoscopy is critical for patient safety and diagnostic accuracy, yet current methods relying on manual adjustments pose risks of improper insufflation. This study aimed to develop an automated gastric pressure control system for flexible endoscopy, addressing these challenges with a piezoresistive pressure sensor that can be integrated into a 7.3 mm diameter flexible endoscope. The system, incorporating air and suction pumps controlled by a microcontroller, was calibrated in an acrylic chamber and validated through comprehensive testing in both an endoscopy simulator and a porcine specimen. Testing scenarios included normal breathing, coughing, belching, and combined events, assessing accuracy, stability, and real-time pressure regulation under conditions mimicking physiological responses. Results demonstrated high accuracy (R<sup>2</sup> = 0.9999), minimal bias (0.23 mmHg), and strong agreement with reference standards, confirming effective pressure management. Simulated clinical scenarios in simulator and porcine specimen further showed the system's ability to maintain target pressure with minimal errors, indicating robustness under dynamic conditions. These findings suggest that the automated pressure control system significantly improves safety and procedural efficiency in endoscopy, with potential applicability to other minimally invasive procedures. Further animal model testing is recommended to validate the clinical performance under realistic physiological conditions.

Medical & Biological Engineering & ComputingVol. 63(4)
Seoul National University (KR), National University College (PR)
Korea Medical Device Development Fund, Seoul National University, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, Ministry of Science and ICT, South Korea
Good health and well-being
Openalex Percentile: Top 59%
Abdominal Surgery and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.