Selection of robust metrics for the position and width of hyperspectral response functions via a simulation approach

The IEEE P4001 hyperspectral camera standard and the need for time-efficient response function test metrics are introduced. Representative center and width metrics applicable to the specification of spatial and spectral response functions are presented. A simulation approach for determining trends in metric behavior as a function of lab collection parameters is described. Algorithm results are enumerated for a variety of hypothetical imager response shapes and width categories under fixed accuracy requirements. Metric flexibility, limiting sample rates, and lab test time estimates are compared and recommendations are made for the P4001 standard. The centroid center metric and standard deviation width algorithm are recommended for both Gaussian and aberrated response shapes when operating at a proposed 5% error tolerance over a specified range of overall response widths, test system scan rates, and electro-optical signal generation levels.

Authors

Institutions

Publication Details

Journal
Applied Optics
Published
2024-12-03
DOI
https://doi.org/10.1364/ao.544074
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Selection of robust metrics for the position and width of hyperspectral response functions via a simulation approach

David Perry, T. Skauli
Applied Optics
Calibration and Measurement Techniques
article

Selection of robust metrics for the position and width of hyperspectral response functions via a simulation approach

David Perry, T. Skauli
article en

Abstract

The IEEE P4001 hyperspectral camera standard and the need for time-efficient response function test metrics are introduced. Representative center and width metrics applicable to the specification of spatial and spectral response functions are presented. A simulation approach for determining trends in metric behavior as a function of lab collection parameters is described. Algorithm results are enumerated for a variety of hypothetical imager response shapes and width categories under fixed accuracy requirements. Metric flexibility, limiting sample rates, and lab test time estimates are compared and recommendations are made for the P4001 standard. The centroid center metric and standard deviation width algorithm are recommended for both Gaussian and aberrated response shapes when operating at a proposed 5% error tolerance over a specified range of overall response widths, test system scan rates, and electro-optical signal generation levels.

Applied OpticsVol. 64(2)
Leidos (United States) (US), Norwegian Defence Research Establishment (NO), University of Oslo (NO)
Openalex Percentile: Top 65%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Selection of robust metrics for the position and width of hyperspectral response functions via a simulation approach — David Perry, T. Skauli · Applied Optics (2024) | TGRS Research Map | TGRS