Continuous Monitoring of Lithium Ions in Lithium-Rich Brine Using Ion Selective Electrode Sensors Modified with Polyelectrolyte Multilayers of Poly(allylamine hydrochloride)/Poly(sodium 4-styrenesulfonate)
Monitoring lithium ions (Li<sup>+</sup>) in lithium-rich brine (LrB) is critical for metal recovery, yet challenges such as high ionic strength and gypsum-induced surface deterioration hinder the performance of potentiometric ion-selective electrode (ISE) sensors. This study advances the functionality of Li<sup>+</sup> ISE sensors and enables continuous monitoring of Li<sup>+</sup> concentration in LrB by introducing apolyelectrolyte multilayer (PEM) of poly(allylamine hydrochloride)/poly(sodium 4-styrenesulfonate) (PAH/PSS) that serves as an antigypsum scaling material to minimize nucleation on the sensor surface. With 5.5 bilayers of PAH/PSS coating, the Li<sup>+</sup> ISE sensors possess a high Nernst slope (59.14 mV/dec), rapid response (<10 s), and superior selectivity against competitive ions (Na<sup>+</sup>, log <i>K</i><sub>s</sub> = -2.35; K<sup>+</sup>, log <i>K</i><sub>s</sub> = -2.47; Ca<sup>2+</sup>, log <i>K</i><sub>s</sub> = -4.05; Mg<sup>2+</sup>, log <i>K</i><sub>s</sub> = -4.18). The impedance (85.1 kΩ) of (PAH/PSS)<sub>5.5</sub>-coated sensors is 1 order of magnitude lower than that of electrospray ion-selective membrane (E-ISM) Li<sup>+</sup> sensors (830 kΩ), attributed to the ultrathin (45.3 nm) and highly dielectric PAH/PSS bilayers. During a 15-day continuous monitoring test in LrB, the (PAH/PSS)<sub>5.5</sub>-coated Li<sup>+</sup> ISE sensors with their superhydrophilic and smooth surface diminish nucleation sites for scaling agents (e.g., Ca<sup>2+</sup> and SO<sub>4</sub><sup>2-</sup>) and consequently mitigate gypsum scaling. Moreover, a brine-tailored denoising data processing algorithm (bt-DDPA), coupled with the salinity-adjusted mathematical model with Lagrange interpolation, effectively captures Li<sup>+</sup> fluctuation by filtering out anomalies and reducing sensor drift in brine. Bt-DDPA alleviates the discrepancy between the sensor readings and the lab-based validation results by 46.06%. This study demonstrates that the integration of material advancement (PAH/PSS coating) with sensor data processing (bt-DDPA) bolsters continuous and accurate Li<sup>+</sup> monitoring in LrB, crucial for brine water treatment and resource recovery.
Authors
- Bryan D. Huey (ORCID: https://orcid.org/0000-0002-1441-1180)
- Baikun Li (ORCID: https://orcid.org/0000-0002-5623-5912)
- Tumilara Aderibigbe
- Jeffrey R. McCutcheon (ORCID: https://orcid.org/0000-0002-5638-4926)
- Xingyu Wang (ORCID: https://orcid.org/0000-0003-4419-6589)
- Fei Wang (ORCID: https://orcid.org/0000-0002-2057-5130)
- Zhiyuan Zhao
- Mi Zhang (ORCID: https://orcid.org/0000-0003-0691-3188)
- Wenjun Xiang (ORCID: https://orcid.org/0000-0001-9418-5808)
- Yingzheng Fan
Institutions
- University of Connecticut (US)
Publication Details
- Journal
- Environmental Science & Technology
- Published
- 2024-12-03
- DOI
- https://doi.org/10.1021/acs.est.4c07155
- Citations
- 3
- Primary Topic
- Analytical Chemistry and Sensors
- Type
- article
- Field-Weighted Citation Impact
- 0.87
Funders
- National Science Foundation
- National Academy of Sciences