Empirical correction decomposition method (ECDM): enhancing accuracy of quantitative measurement in spectral CT

<i>Objective</i>. Spectral CT and material decomposition methods are crucial for precise material identification and quantitative composition analysis in preclinical research and clinical diagnosis. The empirical material decomposition method is widely used for its straightforward modeling approach, independence from spectral and detector response knowledge, and operational convenience. However, this method has limited decomposition accuracy and its precision depends on the choice of calibration phantoms.<i>Approach</i>. To address these issues, we propose an empirical correction decomposition method (ECDM). The innovation of this method lies in its ability to conveniently estimate and correct empirical decomposition errors using a specially designed calibration phantom. First, the specially designed calibration phantom for ECDM undergoes empirical decomposition initially to establish the relationship between decomposition errors and decomposition values. Then, ECDM estimates and corrects the error of empirical decomposition values.<i>Main results</i>. In the phantom experiments, ECDM improves the decomposition accuracy of empirical methods, effectively reducing the different decomposition errors caused by four different sizes of calibration phantoms from a maximum of 144% to within 25%. In the mouse experiments, ECDM achieves accurate quantification of contrast agents in biological tissues, outperforming the other two methods. The absolute error percentages of ECDM in the decomposition results of the two standard iodine solutions are both less than 5%.<i>Significance</i>. ECDM significantly improves decomposition accuracy and reduces the impact of the size of the empirical calibration phantom. Overall, our method based on spectral CT is very convenient and practical for the quantitative measurement in biomedical applications.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-12-03
DOI
https://doi.org/10.1088/1361-6560/ad9a4a
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Empirical correction decomposition method (ECDM): enhancing accuracy of quantitative measurement in spectral CT

Cunfeng Wei, Yuedong Liu, Xiaomei Zhang, Zhe Wang et al.
1 citations
Physics in Medicine and Biology
Advanced X-ray and CT Imaging
0.18
article

Empirical correction decomposition method (ECDM): enhancing accuracy of quantitative measurement in spectral CT

Cunfeng Wei, Yuedong Liu, Xiaomei Zhang, Zhe Wang, Mohan Li, Wei Long, Chengmin Wang
article en
1 citations

Abstract

<i>Objective</i>. Spectral CT and material decomposition methods are crucial for precise material identification and quantitative composition analysis in preclinical research and clinical diagnosis. The empirical material decomposition method is widely used for its straightforward modeling approach, independence from spectral and detector response knowledge, and operational convenience. However, this method has limited decomposition accuracy and its precision depends on the choice of calibration phantoms.<i>Approach</i>. To address these issues, we propose an empirical correction decomposition method (ECDM). The innovation of this method lies in its ability to conveniently estimate and correct empirical decomposition errors using a specially designed calibration phantom. First, the specially designed calibration phantom for ECDM undergoes empirical decomposition initially to establish the relationship between decomposition errors and decomposition values. Then, ECDM estimates and corrects the error of empirical decomposition values.<i>Main results</i>. In the phantom experiments, ECDM improves the decomposition accuracy of empirical methods, effectively reducing the different decomposition errors caused by four different sizes of calibration phantoms from a maximum of 144% to within 25%. In the mouse experiments, ECDM achieves accurate quantification of contrast agents in biological tissues, outperforming the other two methods. The absolute error percentages of ECDM in the decomposition results of the two standard iodine solutions are both less than 5%.<i>Significance</i>. ECDM significantly improves decomposition accuracy and reduces the impact of the size of the empirical calibration phantom. Overall, our method based on spectral CT is very convenient and practical for the quantitative measurement in biomedical applications.

Physics in Medicine and BiologyVol. 70(1)
Chinese Academy of Sciences (CN), University of Jinan (CN), Institute of Vertebrate Paleontology and Paleoanthropology (CN), Beijing Shijingshan Hospital (CN), Key Laboratory of Nuclear Radiation and Nuclear Energy Technology (CN), Institute of High Energy Physics (CN), University of Chinese Academy of Sciences (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 50%
Advanced X-ray and CT Imaging
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.