A Novel Bailout Snare Technique Sparing Recross the Aortic Valve During Transcatheter Aortic Valve Implantation

Transcatheter aortic valve replacement (TAVR) procedure was planned for a 68-year-old female patient diagnosed with severe aortic stenosis by transthoracic echocardiography. The first valve unexpectedly dislodged during catheter tip withdrawal after full deployment. A second valve deployment became necessary, posing challenges due to the difficulty of passing the second valve delivery system through the first valve frame. The snare technique is typically used in cases where there are difficulties in delivering the transcatheter heart valve system across the native aortic valve during the TAVR procedure. We described a novel bailout technique to capture the delivery system in the main access using a snare catheter from the secondary access, while retaining the stiff wire in the left ventricle. This technique could be particularly applicable in scenarios where recrossing is challenging and risky.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2024-12-01
DOI
https://doi.org/10.1002/ccd.31347
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Bailout Snare Technique Sparing Recross the Aortic Valve During Transcatheter Aortic Valve Implantation

Zhengming Jiang, Guangyuan Song, Yao Jing
Catheterization and Cardiovascular Interventions
Cardiac Valve Diseases and Treatments
article

A Novel Bailout Snare Technique Sparing Recross the Aortic Valve During Transcatheter Aortic Valve Implantation

Zhengming Jiang, Guangyuan Song, Yao Jing
article en

Abstract

Transcatheter aortic valve replacement (TAVR) procedure was planned for a 68-year-old female patient diagnosed with severe aortic stenosis by transthoracic echocardiography. The first valve unexpectedly dislodged during catheter tip withdrawal after full deployment. A second valve deployment became necessary, posing challenges due to the difficulty of passing the second valve delivery system through the first valve frame. The snare technique is typically used in cases where there are difficulties in delivering the transcatheter heart valve system across the native aortic valve during the TAVR procedure. We described a novel bailout technique to capture the delivery system in the main access using a snare catheter from the secondary access, while retaining the stiff wire in the left ventricle. This technique could be particularly applicable in scenarios where recrossing is challenging and risky.

Catheterization and Cardiovascular InterventionsVol. 105(1)
Capital Medical University (CN), Beijing Anzhen Hospital (CN)
Good health and well-being
Openalex Percentile: Top 59%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.