NOVEL METHOD FOR DETERMINATION OF POMALIDOMIDE IN HUMAN PLASMA BY ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY MASS SPECTROSCOPY / MASS SPECTROSCOPY

The current investigation studied and verified an accurate Ultra performance liquid chromatography mass spectroscopy/ mass spectroscopy technique for the high-throughput detection of pomalidomide in human plasma with celecoxib as an internal standard. Chromatographic studies were carried out on Hypersil BDS (50 mm x 4.1 mm, 5m) with an isocratic mobile phase of acetonitrile: ammonium formate (80:20, V/V), at a flow rate of 0.5 mL min-1 and a total run time of 3 min. A triple quadruple Tandem Mass spectroscopy with electrospray ionization in positive mode was utilized to identify the analyte. Using multiple reaction monitoring modes and precursor-to-product ion transitions of 274.43 m/z for pomalidomide and 382.12 m/z for standard, respectively, pomalidomide and internal standard were measured. The developed technique was verified as per the regulatory standards for bioanalytical procedures validation. Other validation results also match.

Authors

Publication Details

Journal
INDIAN DRUGS
Published
2024-10-28
DOI
https://doi.org/10.53879/id.61.10.14252
Primary Topic
Advanced Drug Delivery Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

NOVEL METHOD FOR DETERMINATION OF POMALIDOMIDE IN HUMAN PLASMA BY ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY MASS SPECTROSCOPY / MASS SPECTROSCOPY

Senthilkumar Natesan, Kalaiselvi Ponnusamy, Thangavel Venkatachalam, Kathiravan Natarasan et al.
INDIAN DRUGS
Advanced Drug Delivery Systems
article

NOVEL METHOD FOR DETERMINATION OF POMALIDOMIDE IN HUMAN PLASMA BY ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY MASS SPECTROSCOPY / MASS SPECTROSCOPY

Senthilkumar Natesan, Kalaiselvi Ponnusamy, Thangavel Venkatachalam, Kathiravan Natarasan, Hariprakash Kandasamy
article en

Abstract

The current investigation studied and verified an accurate Ultra performance liquid chromatography mass spectroscopy/ mass spectroscopy technique for the high-throughput detection of pomalidomide in human plasma with celecoxib as an internal standard. Chromatographic studies were carried out on Hypersil BDS (50 mm x 4.1 mm, 5m) with an isocratic mobile phase of acetonitrile: ammonium formate (80:20, V/V), at a flow rate of 0.5 mL min-1 and a total run time of 3 min. A triple quadruple Tandem Mass spectroscopy with electrospray ionization in positive mode was utilized to identify the analyte. Using multiple reaction monitoring modes and precursor-to-product ion transitions of 274.43 m/z for pomalidomide and 382.12 m/z for standard, respectively, pomalidomide and internal standard were measured. The developed technique was verified as per the regulatory standards for bioanalytical procedures validation. Other validation results also match.

INDIAN DRUGSVol. 61(10)
Openalex Percentile: Top 83%
Advanced Drug Delivery Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.