Challenges for the Implementation of Primary Standard Dosimetry in Proton Minibeam Radiation Therapy

<b>Background/Objectives</b>: Spatial fractionation of proton fields as sub-millimeter beamlets to treat cancer has shown better sparing of healthy tissue whilst maintaining the same tumor control. It is critical to ensure primary standard dosimetry is accurate and ready to support the modality's clinical implementation. <b>Methods</b>: This work provided a proof-of-concept, using the National Physical Laboratory's Primary Standard Proton Calorimeter (PSPC) to measure average absorbed dose-to-water in a pMBRT field. A 100 MeV mono-energetic field and a 2 cm wide SOBP were produced with a spot-scanned proton beam incident on a collimator comprising 15 slits of 400 µm width, each 5 cm long and separated by a center-to-center distance of 4 mm. <b>Results</b>: The results showed the uncertainty on the absorbed dose-to-water in the mono-energetic beam was dominated by contributions of 1.4% and 1.1% (k = 1) for the NPL PSPC and PTW Roos chambers, respectively, originating from the achievable positioning accuracy of the devices. In comparison, the uncertainty due to positioning in the SOBP for both the NPL PSPC and PTW Roos chambers were 0.4%. <b>Conclusions</b>: These results highlight that it may be more accurate and reliable to perform reference dosimetry measuring the Dose-Area Product or in an SOBP for spatially fractionated fields.

Authors

Institutions

Publication Details

Journal
Cancers
Published
2024-11-29
DOI
https://doi.org/10.3390/cancers16234013
Citations
1
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Challenges for the Implementation of Primary Standard Dosimetry in Proton Minibeam Radiation Therapy

Ludovic De Marzi, Michael Homer, Yolanda Prezado, Samuel Flynn et al.
1 citations
Cancers
Radiation Therapy and Dosimetry
0.42
article

Challenges for the Implementation of Primary Standard Dosimetry in Proton Minibeam Radiation Therapy

Ludovic De Marzi, Michael Homer, Yolanda Prezado, Samuel Flynn, Hugo Palmans, Anna Subiel, J.A. COTTERILL, Nigel Lee, Russell Thomas, D R Shipley, Ana Lourenço
article en
1 citations

Abstract

<b>Background/Objectives</b>: Spatial fractionation of proton fields as sub-millimeter beamlets to treat cancer has shown better sparing of healthy tissue whilst maintaining the same tumor control. It is critical to ensure primary standard dosimetry is accurate and ready to support the modality's clinical implementation. <b>Methods</b>: This work provided a proof-of-concept, using the National Physical Laboratory's Primary Standard Proton Calorimeter (PSPC) to measure average absorbed dose-to-water in a pMBRT field. A 100 MeV mono-energetic field and a 2 cm wide SOBP were produced with a spot-scanned proton beam incident on a collimator comprising 15 slits of 400 µm width, each 5 cm long and separated by a center-to-center distance of 4 mm. <b>Results</b>: The results showed the uncertainty on the absorbed dose-to-water in the mono-energetic beam was dominated by contributions of 1.4% and 1.1% (k = 1) for the NPL PSPC and PTW Roos chambers, respectively, originating from the achievable positioning accuracy of the devices. In comparison, the uncertainty due to positioning in the SOBP for both the NPL PSPC and PTW Roos chambers were 0.4%. <b>Conclusions</b>: These results highlight that it may be more accurate and reliable to perform reference dosimetry measuring the Dose-Area Product or in an SOBP for spatially fractionated fields.

CancersVol. 16(23)
Centre National de la Recherche Scientifique (FR), National Physical Laboratory (GB), Inserm (FR), Universidade de Santiago de Compostela (ES), Université Paris Sciences et Lettres (FR), Université Paris-Saclay (FR), Xunta de Galicia (ES), University of Surrey (GB), Institut d'Imagerie Biomédicale (FR), Center for Research in Molecular Medicine and Chronic Diseases (ES), Instituto de Investigación Sanitaria de Santiago (ES), MedAustron (AT), University College London (GB), University of Birmingham (GB), Institut Curie (FR)
Good health and well-being
Openalex Percentile: Top 30%
Radiation Therapy and Dosimetry
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.