Complementary Metal Oxide Semiconductor-Based Optical Detection System for Fluidic Cellular Medium pH Quantification

Accurate pH sensing is essential for the effective physiological control of the culture media in organ-on-a-chip (OoC) systems. This work proposes a miniaturized optical detection system, based on optical transmittance, for pH level quantification of the EGM™-2 Endothelial Cell Growth Medium-2 BulletKit™ culture medium. Firstly, using a commercial spectrophotometric setup, a set of wavelengths (500, 560, and 600 nm) was selected, as these wavelengths assure distinctive slope variations for the different pH levels. Then, a current-to-frequency converter, based on a low-power Schmitt trigger model with a voltage enhancer, was proposed as the readout electronics and simulated in Cadence Tools using UMC L180 MM/RF technology. A resolution of 0.002 nA was achieved in the linear range of 30 pA to 3800 nA. A miniaturized system composed of a CMOS n-well/p-substrate photodiode and a polydimethilsiloxane (PDMS) microchannel for the culture media substrate was experimentally tested. For a pH range from 6.6 to 6.2, the results clearly demonstrate a magnitude shift of the slope signal, which becomes negative in basic media and positive in acidic media. Additionally, in the 500–560 nm spectral range, the amplitude of the slopes increases for both basic and acidic culture media. In the 560–600 nm range, the slope decreases progressively as the pH of the medium lowers. This miniaturized system was able to quantify the pH of the culture medium, showing potential to be integrated into an organ-on-a-chip device.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2024-11-29
DOI
https://doi.org/10.3390/photonics11121130
Citations
4
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Complementary Metal Oxide Semiconductor-Based Optical Detection System for Fluidic Cellular Medium pH Quantification

Gabriel M. Ferreira, Susana Oliveira Catarino, Ana Alice D. Santos, Patrícia C. Sousa et al.
4 citations
Photonics
Analytical Chemistry and Sensors
1.16
article

Complementary Metal Oxide Semiconductor-Based Optical Detection System for Fluidic Cellular Medium pH Quantification

Gabriel M. Ferreira, Susana Oliveira Catarino, Ana Alice D. Santos, Patrícia C. Sousa, Paulo Sousa, Graça Minas
article en
4 citations

Abstract

Accurate pH sensing is essential for the effective physiological control of the culture media in organ-on-a-chip (OoC) systems. This work proposes a miniaturized optical detection system, based on optical transmittance, for pH level quantification of the EGM™-2 Endothelial Cell Growth Medium-2 BulletKit™ culture medium. Firstly, using a commercial spectrophotometric setup, a set of wavelengths (500, 560, and 600 nm) was selected, as these wavelengths assure distinctive slope variations for the different pH levels. Then, a current-to-frequency converter, based on a low-power Schmitt trigger model with a voltage enhancer, was proposed as the readout electronics and simulated in Cadence Tools using UMC L180 MM/RF technology. A resolution of 0.002 nA was achieved in the linear range of 30 pA to 3800 nA. A miniaturized system composed of a CMOS n-well/p-substrate photodiode and a polydimethilsiloxane (PDMS) microchannel for the culture media substrate was experimentally tested. For a pH range from 6.6 to 6.2, the results clearly demonstrate a magnitude shift of the slope signal, which becomes negative in basic media and positive in acidic media. Additionally, in the 500–560 nm spectral range, the amplitude of the slopes increases for both basic and acidic culture media. In the 560–600 nm range, the slope decreases progressively as the pH of the medium lowers. This miniaturized system was able to quantify the pH of the culture medium, showing potential to be integrated into an organ-on-a-chip device.

PhotonicsVol. 11(12)
International Iberian Nanotechnology Laboratory (PT), University of Minho (PT)
Foundation for Science and Technology, Fundação para a Ciência e a Tecnologia
Clean water and sanitation
Openalex Percentile: Top 24%
Analytical Chemistry and Sensors
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.