Monitoring Indoor Air Quality in Classrooms Using Low-Cost Sensors: Does the Perception of Teachers Match Reality?

This study intended to understand whether teachers’ perceptions of indoor air quality (IAQ) during classes aligned with the real levels of air pollutants and comfort parameters. For this purpose, an IAQ monitoring survey based on low-cost sensors using a multi-parameter approach was carried out in nine classrooms (a total of 171 monitored classes) in a Portuguese school. In each monitored class, the perception of IAQ reported by the teacher was assessed using a scale from 1 (very bad IAQ) to 10 (very good IAQ). Several exceedances regarding national legislation were found, with temperature being the parameter with a higher percentage of exceedance in all the studied classrooms (46%), followed by PM10 (32%), and then CO2 (27%). Temperature was found to be the only environmental parameter that was significantly associated with lower IAQ perception reported by the teachers, highlighting that typical pollutants such as CO2 (which can be identified as stuffy air) did not contribute to the teachers’ perceptions.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2024-12-01
DOI
https://doi.org/10.3390/atmos15121450
Citations
13
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
4.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring Indoor Air Quality in Classrooms Using Low-Cost Sensors: Does the Perception of Teachers Match Reality?

Nuno Canha, Sergio Mendez, Miguel Felizardo, Carolina Correia et al.
13 citations
Atmosphere
Indoor Air Quality and Microbial Exposure
4.09
article

Monitoring Indoor Air Quality in Classrooms Using Low-Cost Sensors: Does the Perception of Teachers Match Reality?

Nuno Canha, Sergio Mendez, Miguel Felizardo, Carolina Correia, Carla A. Gamelas
article en
13 citations

Abstract

This study intended to understand whether teachers’ perceptions of indoor air quality (IAQ) during classes aligned with the real levels of air pollutants and comfort parameters. For this purpose, an IAQ monitoring survey based on low-cost sensors using a multi-parameter approach was carried out in nine classrooms (a total of 171 monitored classes) in a Portuguese school. In each monitored class, the perception of IAQ reported by the teacher was assessed using a scale from 1 (very bad IAQ) to 10 (very good IAQ). Several exceedances regarding national legislation were found, with temperature being the parameter with a higher percentage of exceedance in all the studied classrooms (46%), followed by PM10 (32%), and then CO2 (27%). Temperature was found to be the only environmental parameter that was significantly associated with lower IAQ perception reported by the teachers, highlighting that typical pollutants such as CO2 (which can be identified as stuffy air) did not contribute to the teachers’ perceptions.

AtmosphereVol. 15(12)
University of Lisbon (PT), Universidade Politécnica de Setúbal (PT)
Fundação para a Ciência e a Tecnologia
Quality Education
Openalex Percentile: Top 5%
Indoor Air Quality and Microbial Exposure
4.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.