Accuracy of Aneroid Versus Digital Sphygmomanometer in Community-Based Screening for Hypertension in Hubballi, Karnataka, India - A Cross-Sectional Study

Background: Hypertension is a significant global health issue, responsible for approximately 7.5 million deaths annually. Even a modest increase of 5 mm Hg in systolic blood pressure (BP) can elevate the risk of fatal stroke and infarction by about 25%. Hence this study aimed to assess the accuracy of aneroid and digital sphygmomanometers relative to the mercury sphygmomanometer. Methodology: This community-based cross-sectional study was conducted in the urban slums of old Hubballi among 270 participants aged 30 years and above. Participants were selected using Probability Proportion to Size from 3 wards. Blood pressures were measured with all three sphygmomanometers and Bland Altman plot analysis was done. Results: The results revealed that the mean difference in systolic blood pressure compared to mercury was -0.57 mmHg for the aneroid and -4.63 mmHg for the digital (p <0.05). For diastolic blood pressure, the mean difference was -0.39 mmHg for the aneroid and -3.43 mmHg for the digital (p <0.05). Bland-Altman analysis showed agreement limits of 66.3% for systolic and 75.2% for diastolic blood pressure with the aneroid sphygmomanometer. Conclusion: The aneroid sphygmomanometer provides more reliable BP readings compared to the digital sphygmomanometer for both systolic and diastolic measurements.

Authors

Institutions

Publication Details

Journal
National Journal of Community Medicine
Published
2024-12-01
DOI
https://doi.org/10.55489/njcm.151220244689
Primary Topic
Diverse Scientific Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Aneroid Versus Digital Sphygmomanometer in Community-Based Screening for Hypertension in Hubballi, Karnataka, India - A Cross-Sectional Study

Kashavva B Andanigoudar, N Roopakala, Mahesh D. Kurugodiyavar
National Journal of Community Medicine
Diverse Scientific Research Studies
article

Accuracy of Aneroid Versus Digital Sphygmomanometer in Community-Based Screening for Hypertension in Hubballi, Karnataka, India - A Cross-Sectional Study

Kashavva B Andanigoudar, N Roopakala, Mahesh D. Kurugodiyavar
article en

Abstract

Background: Hypertension is a significant global health issue, responsible for approximately 7.5 million deaths annually. Even a modest increase of 5 mm Hg in systolic blood pressure (BP) can elevate the risk of fatal stroke and infarction by about 25%. Hence this study aimed to assess the accuracy of aneroid and digital sphygmomanometers relative to the mercury sphygmomanometer. Methodology: This community-based cross-sectional study was conducted in the urban slums of old Hubballi among 270 participants aged 30 years and above. Participants were selected using Probability Proportion to Size from 3 wards. Blood pressures were measured with all three sphygmomanometers and Bland Altman plot analysis was done. Results: The results revealed that the mean difference in systolic blood pressure compared to mercury was -0.57 mmHg for the aneroid and -4.63 mmHg for the digital (p <0.05). For diastolic blood pressure, the mean difference was -0.39 mmHg for the aneroid and -3.43 mmHg for the digital (p <0.05). Bland-Altman analysis showed agreement limits of 66.3% for systolic and 75.2% for diastolic blood pressure with the aneroid sphygmomanometer. Conclusion: The aneroid sphygmomanometer provides more reliable BP readings compared to the digital sphygmomanometer for both systolic and diastolic measurements.

National Journal of Community MedicineVol. 15(12)
Navodaya Dental College and Hospital (IN), Karnataka Institute of Medical Sciences (IN)
Good health and well-being
Openalex Percentile: Top 61%
Diverse Scientific Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of Aneroid Versus Digital Sphygmomanometer in Community-Based Screening for Hypertension in Hubballi, Karnataka, India - A Cross-Sectional Study — Kashavva B Andanigoudar, N Roopakala, et al. · National Journal of Community Medicine (2024) | TGRS Research Map | TGRS