Sheath-enhanced concentration and on-chip detection of bacteria from an extremely low-concentration level

Microfluidic-based sheath flow focusing methods have been widely used for efficiently isolating, concentrating, and detecting pathogenic bacteria for various biomedical applications due to their enhanced sensitivity and exceptional integration. However, such a microfluidic device usually needs complicated device fabrication and sample dilution, hampering the efficient and sensitive identification of target bacteria. In this study, we develop and fabricate a sheath-assisted and pneumatic-induced nano-sieve device for achieving the improved on-chip concentration and sensitive detection of <i>Staphylococcus aureus</i> (MRSA). The optimized nanochannel design with diverging configuration is beneficial to the regulation of the hydrodynamic flow while the sheath flow is focusing the sample to the confined region as expected. Per the experimental finding, a high flow ratio (sheath flow/sample flow) presents enhanced target concentration by comparing with a low flow ratio. With this setup, MRSA bacteria with an extremely low concentration of ∼100 CFU mL<sup>-1</sup> are successfully and sensitively detected under a fluorescence microscope, less than 30 min, demonstrating a reliable sheath-enhanced concentration and on-chip detection for target bacteria. Additionally, the theoretical model introduced here further rationalizes the working principle of our nano-sieve device, potentially guiding the optimization of next generation devices for highly sensitive and accurate on-chip bacteria detection at a much lower concentration level below 100 CFU mL<sup>-1</sup>.

Authors

Institutions

Publication Details

Journal
Lab on a Chip
Published
2024-12-03
DOI
https://doi.org/10.1039/d4lc00698d
Citations
3
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sheath-enhanced concentration and on-chip detection of bacteria from an extremely low-concentration level

Ruo‐Qian Wang, Xinye Chen, Ruonan Peng, Ke Du
3 citations
Lab on a Chip
Microfluidic and Capillary Electrophoresis Applications
0.55
article

Sheath-enhanced concentration and on-chip detection of bacteria from an extremely low-concentration level

Ruo‐Qian Wang, Xinye Chen, Ruonan Peng, Ke Du
article en
3 citations

Abstract

Microfluidic-based sheath flow focusing methods have been widely used for efficiently isolating, concentrating, and detecting pathogenic bacteria for various biomedical applications due to their enhanced sensitivity and exceptional integration. However, such a microfluidic device usually needs complicated device fabrication and sample dilution, hampering the efficient and sensitive identification of target bacteria. In this study, we develop and fabricate a sheath-assisted and pneumatic-induced nano-sieve device for achieving the improved on-chip concentration and sensitive detection of <i>Staphylococcus aureus</i> (MRSA). The optimized nanochannel design with diverging configuration is beneficial to the regulation of the hydrodynamic flow while the sheath flow is focusing the sample to the confined region as expected. Per the experimental finding, a high flow ratio (sheath flow/sample flow) presents enhanced target concentration by comparing with a low flow ratio. With this setup, MRSA bacteria with an extremely low concentration of ∼100 CFU mL<sup>-1</sup> are successfully and sensitively detected under a fluorescence microscope, less than 30 min, demonstrating a reliable sheath-enhanced concentration and on-chip detection for target bacteria. Additionally, the theoretical model introduced here further rationalizes the working principle of our nano-sieve device, potentially guiding the optimization of next generation devices for highly sensitive and accurate on-chip bacteria detection at a much lower concentration level below 100 CFU mL<sup>-1</sup>.

Lab on a ChipVol. 25(9)
Rutgers, The State University of New Jersey (US), University of California, Riverside (US)
Openalex Percentile: Top 36%
Microfluidic and Capillary Electrophoresis Applications
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sheath-enhanced concentration and on-chip detection of bacteria from an extremely low-concentration level — Ruo‐Qian Wang, Xinye Chen, et al. · Lab on a Chip (2024) | TGRS Research Map | TGRS