Optimization concrete shielding composition composed of different minerals for neutron and gamma radiation emitted from 18 MeV Linac using Monte-Carlo simulation

This study was conducted to find the best combined ratio of galena, hematite and limonite in concrete shielding structure against neutron and gamma rays emitted from 18 MeV Linac source in radiation therapy centers. The MCNPX code was used to calculate the linear attenuation coefficient of different concretes for the 18 MeV Linac source. The concrete samples were then produced in a laboratory, and their compressive strength was measured. Then, by comparing the quality factor diagrams that simultaneously express the power of neutron and gamma attenuation and compressive strength, the optimal point for the percentage of different minerals in concrete was identified. The results showed that the used minerals have a high gamma absorption capacity due to their high atomic number and density. It also showed that the neutron attenuation power increases with the increase in the concentration of galena, limonite, hematite in concrete and reaches to its maximum value. And if the concentration of minerals rises above a certain value, the neutron attenuation power of concrete decreases, due to the decrease in the concentration of lighter elements such as hydrogen in the concrete structure, as well as the increase in the probability of secondary neutrons production. The highest value of QF was obtained for samples containing 40% galena, 50% hematite and 40% limonite, and the highest value of QF/ ρ was obtained for samples G 30 , G 40 , H 50 , L 30 and L 40 . This type of concretes can be used to create an effective concrete shield for radiotherapy centers.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research and Applied Sciences
Published
2024-12-01
DOI
https://doi.org/10.1016/j.jrras.2024.101223
Citations
4
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
0.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization concrete shielding composition composed of different minerals for neutron and gamma radiation emitted from 18 MeV Linac using Monte-Carlo simulation

Seyed Mohsen Mortazavi Shahroudi, Reza Pourimani, Tasnim Hassan, Goodarzi Masumeh
4 citations
Journal of Radiation Research and Applied Sciences
Radiation Shielding Materials Analysis
0.47
article

Optimization concrete shielding composition composed of different minerals for neutron and gamma radiation emitted from 18 MeV Linac using Monte-Carlo simulation

Seyed Mohsen Mortazavi Shahroudi, Reza Pourimani, Tasnim Hassan, Goodarzi Masumeh
article en
4 citations

Abstract

This study was conducted to find the best combined ratio of galena, hematite and limonite in concrete shielding structure against neutron and gamma rays emitted from 18 MeV Linac source in radiation therapy centers. The MCNPX code was used to calculate the linear attenuation coefficient of different concretes for the 18 MeV Linac source. The concrete samples were then produced in a laboratory, and their compressive strength was measured. Then, by comparing the quality factor diagrams that simultaneously express the power of neutron and gamma attenuation and compressive strength, the optimal point for the percentage of different minerals in concrete was identified. The results showed that the used minerals have a high gamma absorption capacity due to their high atomic number and density. It also showed that the neutron attenuation power increases with the increase in the concentration of galena, limonite, hematite in concrete and reaches to its maximum value. And if the concentration of minerals rises above a certain value, the neutron attenuation power of concrete decreases, due to the decrease in the concentration of lighter elements such as hydrogen in the concrete structure, as well as the increase in the probability of secondary neutrons production. The highest value of QF was obtained for samples containing 40% galena, 50% hematite and 40% limonite, and the highest value of QF/ ρ was obtained for samples G 30 , G 40 , H 50 , L 30 and L 40 . This type of concretes can be used to create an effective concrete shield for radiotherapy centers.

Journal of Radiation Research and Applied SciencesVol. 18(1)
Baqiyatallah University of Medical Sciences (IR), Arak University (IR)
Baqiyatallah University of Medical Sciences
Sustainable cities and communities
Openalex Percentile: Top 37%
Radiation Shielding Materials Analysis
0.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.