A numerical study of the effect of  different geometrical parameters on the cooling processes  in electrical transformer

Proper thermal control is one of the most important aspects that should be considered when utilizing electrical transformers. This research work offers a numerical analysis of the effect of changing the shape of transformer fins on the heat exchange process. Based on the results of CFD simulations, several types of fin shapes such as rectangular, triangular and wavy are discussed to describe the improvements of heat transfer. The study examines the shape of an electrical transformer, determining the optimal distance between fins, fin shapes, transformer shape, rib type, and rib number. The results are then applied to a special case, representing the best of all variables on the transformer. The study also considers the effect of increasing the surface area of the ribs on the fins, and the number of ribs used on the fins. The temperature gradient of a coil, oil, and transformer varies depending on the distance between fins, fin shape, rib type, and number of ribs. The coil temperature is 383 K when the fins are 7 cm apart, 381 K when the fins are 5 cm apart, and 381 K when the fins are 3cm apart. The temperature gradient also varies depending on the rib type, with triangular ribs increasing the surface area for heat energy transfer and reducing the temperature value. The oil temperature gradient varies depending on the fins, ribs type, and number of ribs. The heat transfer coefficient gradient of the transformer surface varies depending on the fins, ribs type, and number of ribs. The surface heat transfer coefficient reaches 1.5 W/m2. K when the fins are l shape, 1.6 W/m2. K when the fins are c shape, 1.7 W/m2. K when the fins are z shape, 1.4 W/m2. K when the ribs are rectangular, 1.6 W/m2. K when the ribs are triangular, and 1.4 W/m2. K when the ribs are 9 ribs.

Authors

Institutions

Publication Details

Journal
Wasit Journal of Engineering Sciences
Published
2024-12-01
DOI
https://doi.org/10.31185/ejuow.vol12.iss4.576
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A numerical study of the effect of  different geometrical parameters on the cooling processes  in electrical transformer

Hadi Basher, M. N. Mohammed
1 links
Wasit Journal of Engineering Sciences
Power Transformer Diagnostics and Insulation
article

A numerical study of the effect of  different geometrical parameters on the cooling processes  in electrical transformer

Hadi Basher, M. N. Mohammed
article en

Abstract

Proper thermal control is one of the most important aspects that should be considered when utilizing electrical transformers. This research work offers a numerical analysis of the effect of changing the shape of transformer fins on the heat exchange process. Based on the results of CFD simulations, several types of fin shapes such as rectangular, triangular and wavy are discussed to describe the improvements of heat transfer. The study examines the shape of an electrical transformer, determining the optimal distance between fins, fin shapes, transformer shape, rib type, and rib number. The results are then applied to a special case, representing the best of all variables on the transformer. The study also considers the effect of increasing the surface area of the ribs on the fins, and the number of ribs used on the fins. The temperature gradient of a coil, oil, and transformer varies depending on the distance between fins, fin shape, rib type, and number of ribs. The coil temperature is 383 K when the fins are 7 cm apart, 381 K when the fins are 5 cm apart, and 381 K when the fins are 3cm apart. The temperature gradient also varies depending on the rib type, with triangular ribs increasing the surface area for heat energy transfer and reducing the temperature value. The oil temperature gradient varies depending on the fins, ribs type, and number of ribs. The heat transfer coefficient gradient of the transformer surface varies depending on the fins, ribs type, and number of ribs. The surface heat transfer coefficient reaches 1.5 W/m2. K when the fins are l shape, 1.6 W/m2. K when the fins are c shape, 1.7 W/m2. K when the fins are z shape, 1.4 W/m2. K when the ribs are rectangular, 1.6 W/m2. K when the ribs are triangular, and 1.4 W/m2. K when the ribs are 9 ribs.

Wasit Journal of Engineering SciencesVol. 12(4)
University of Wasit (IQ)
Affordable and clean energy
Openalex Percentile: Top 81%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.