Accuracy of the Set Tidal Volume During Intraoperative Anesthetic Care: An <i>In Vitro</i> Evaluation

Background: Precise adjustment of tidal volume (Vt) and minute ventilation remains a key component of intraoperative care. Control of Vt is regulated by internal pneumotachometers and flow meters, which may be separated from the patient by the anesthesia circuit and the internal circuitry of the anesthesia machine. Given this arrangement, there may be variations in delivered and exhaled (measured) Vt depending on the site of measurement. Methods: The current study used an in vitro model to determine variations in inspired and expired Vt during various volume- and pressure-controlled modes of ventilation using an Avance CS 2 anesthesia machine. Results: During in vitro mechanical ventilation using pressure limited (15 and 20 cm H 2 O) and volume limited (Vt 50, 100, 200, and 300 mL), we saw slight discrepancies between Vt measured using a pneumotachometer placed between the endotracheal tube (ETT) and the anesthesia circuit as compared to those measured internally by the anesthesia machine. Conclusions: Although the differences were statistically significant, the variations were no more than 5-6% at most at the higher Vt with either volume- or pressure-limited ventilation. These differences are unlikely to be clinically significant, thereby demonstrating the accuracy and safety of anesthesia machines from the modern era. Int J Clin Pediatr. 2024;13(3):69-72 doi: https://doi.org/10.14740/ijcp551

Authors

Institutions

Publication Details

Journal
International Journal of Clinical Pediatrics
Published
2024-12-01
DOI
https://doi.org/10.14740/ijcp551
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of the Set Tidal Volume During Intraoperative Anesthetic Care: An In Vitro Evaluation

Michael Tobias, Kelly Moon, Julie Rice‐Weimer, Joseph D. Tobias et al.
International Journal of Clinical Pediatrics
Hemodynamic Monitoring and Therapy
article

Accuracy of the Set Tidal Volume During Intraoperative Anesthetic Care: An In Vitro Evaluation

Michael Tobias, Kelly Moon, Julie Rice‐Weimer, Joseph D. Tobias, Jennifer Sawyer
article en

Abstract

Background: Precise adjustment of tidal volume (Vt) and minute ventilation remains a key component of intraoperative care. Control of Vt is regulated by internal pneumotachometers and flow meters, which may be separated from the patient by the anesthesia circuit and the internal circuitry of the anesthesia machine. Given this arrangement, there may be variations in delivered and exhaled (measured) Vt depending on the site of measurement. Methods: The current study used an in vitro model to determine variations in inspired and expired Vt during various volume- and pressure-controlled modes of ventilation using an Avance CS 2 anesthesia machine. Results: During in vitro mechanical ventilation using pressure limited (15 and 20 cm H 2 O) and volume limited (Vt 50, 100, 200, and 300 mL), we saw slight discrepancies between Vt measured using a pneumotachometer placed between the endotracheal tube (ETT) and the anesthesia circuit as compared to those measured internally by the anesthesia machine. Conclusions: Although the differences were statistically significant, the variations were no more than 5-6% at most at the higher Vt with either volume- or pressure-limited ventilation. These differences are unlikely to be clinically significant, thereby demonstrating the accuracy and safety of anesthesia machines from the modern era. Int J Clin Pediatr. 2024;13(3):69-72 doi: https://doi.org/10.14740/ijcp551

International Journal of Clinical PediatricsVol. 13(3)
Nationwide Children's Hospital (US), Ohio University (US)
Openalex Percentile: Top 59%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.