Quality of River Water in the District Area of Middle of Java

The decline in river air quality is characterized by a decline in air quality parameters, namely physical, chemical and microbiological parameters. Preliminary studies revealed that the physical and chemical parameters of TSS, BOD were respectively 52 mg/L, 57 mg/L, the test results were not in accordance with Government Regulation no. 22 of 2021 concerning Implementation of Environmental Protection and Management. The aim of this research is to determine the quality of river water based on physical and chemical parameters, namely Total Suspended Solid (TSS), Total Dissolved Solid (TDS), Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD), Dissolved Oxygen (DO), water potential hydrogen (pH) in Karanganyar Regency. This research method is quantitative descriptive using laboratory tests, with samples from 6 rivers in each sub-watershed. The sampling technique uses Integrated Sampling by carrying out laboratory testing. Data analysis uses air quality measurements using the pollutant index method. The parameters tested are physical parameters, namely TSS, TDS and chemical parameters, namely COD, BOD, DO and pH. The research results show that the TSS parameters exceed the quality standards, TDS corresponds to the quality standards, COD exceeds the quality standards, BOD exceeds the quality standards, DO corresponds to the quality standards, pH does not comply with the quality standards. The conclusions in this research are that the Jlamprang River sub-watershed of Kudus is 1.99 (lightly polluted), the Bagor River is sub-watershed of Jlantah 2.31 (lightly polluted), the Gembong River is sub-watershed of Samin 6.94 (moderately polluted), the Kumpul River is sub-watershed of Mungkung 2 .74 (lightly polluted), Kendat River, Kenatan sub-watershed, 2.67 (lightly polluted), Pepe River, Pepe sub-watershed, 2.14 (lightly polluted). The suggestion for the Karanganyar District Government is to monitor river water quality regularly Keywords: Chemical Oxygen Demand, Biological Oxygen Demand, Dissolved Oxygen.

Authors

Institutions

Publication Details

Journal
Media Karya Kesehatan
Published
2024-11-28
DOI
https://doi.org/10.24198/mkk.v7i2.53067
Primary Topic
Water Quality Monitoring Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quality of River Water in the District Area of Middle of Java

Fiqi Nurbaya, Yohana Fide Oktavia, Syefira Ayodia Johar
Media Karya Kesehatan
Water Quality Monitoring Technologies
article

Quality of River Water in the District Area of Middle of Java

Fiqi Nurbaya, Yohana Fide Oktavia, Syefira Ayodia Johar
article en

Abstract

The decline in river air quality is characterized by a decline in air quality parameters, namely physical, chemical and microbiological parameters. Preliminary studies revealed that the physical and chemical parameters of TSS, BOD were respectively 52 mg/L, 57 mg/L, the test results were not in accordance with Government Regulation no. 22 of 2021 concerning Implementation of Environmental Protection and Management. The aim of this research is to determine the quality of river water based on physical and chemical parameters, namely Total Suspended Solid (TSS), Total Dissolved Solid (TDS), Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD), Dissolved Oxygen (DO), water potential hydrogen (pH) in Karanganyar Regency. This research method is quantitative descriptive using laboratory tests, with samples from 6 rivers in each sub-watershed. The sampling technique uses Integrated Sampling by carrying out laboratory testing. Data analysis uses air quality measurements using the pollutant index method. The parameters tested are physical parameters, namely TSS, TDS and chemical parameters, namely COD, BOD, DO and pH. The research results show that the TSS parameters exceed the quality standards, TDS corresponds to the quality standards, COD exceeds the quality standards, BOD exceeds the quality standards, DO corresponds to the quality standards, pH does not comply with the quality standards. The conclusions in this research are that the Jlamprang River sub-watershed of Kudus is 1.99 (lightly polluted), the Bagor River is sub-watershed of Jlantah 2.31 (lightly polluted), the Gembong River is sub-watershed of Samin 6.94 (moderately polluted), the Kumpul River is sub-watershed of Mungkung 2 .74 (lightly polluted), Kendat River, Kenatan sub-watershed, 2.67 (lightly polluted), Pepe River, Pepe sub-watershed, 2.14 (lightly polluted). The suggestion for the Karanganyar District Government is to monitor river water quality regularly Keywords: Chemical Oxygen Demand, Biological Oxygen Demand, Dissolved Oxygen.

Media Karya KesehatanVol. 7(2)
WiLAN (Canada) (CA), Universitas Bangun Nusantara (ID)
Clean water and sanitation
Openalex Percentile: Top 79%
Water Quality Monitoring Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines