Real-time neurochemical sensing of hydrogen peroxide production in brain tissue using advanced nanostructured Au microelectrodes functionalized with a ruthenium purple film

Real-time monitoring of H 2 O 2 is essential for understanding its role in neurological physio(path)ology. In this study, we developed an advanced electrochemical sensor utilizing nanostructured gold wire microelectrodes functionalized with a Ruthenium Purple (RP) film, a polynuclear transition metal hexacyanoferrate analog of the prototypical Prussian blue (PB). The RP film exhibits enhanced stability in neutral buffer solutions and reduced interference from biologically relevant cations such as Na + , Mg 2+ , and Ca 2+ . By integrating gold nanoparticles onto a nanoporous gold surface, we significantly increased the electroactive surface area of the microwire (ρ=26.1 ± 10.2). The electrodeposition of a thin RP film (4.23 ± 1.2 nm) resulted in a highly selective H 2 O 2 sensor, operating at an optimal potential of -0.05 V vs. Ag/AgCl, with a linear detection range of 0.5-500 µM, sensitivity of 1.18 ± 0.37 µA µM -1 cm -2 , and a low limit of detection (LOD) of 66.6 ± 34.9 nM. Adding a Nafion® layer enhanced the sensor's operational stability, maintaining optimal performance over three hours under physiological conditions of pH and ion concentration. We validated the sensor's capability to monitor transient changes in H 2 O 2 concentration in brain tissue by assessing its response to exogenously applied H 2 O 2 . Furthermore, we demonstrated that glutamate receptor activation in hippocampal slices induces a rapid and transient increase in extracellular H 2 O 2 levels, underscoring the sensor's potential for studying oxidative stress in neurobiological contexts.

Authors

Institutions

Publication Details

Journal
Electrochimica Acta
Published
2024-12-01
DOI
https://doi.org/10.1016/j.electacta.2024.145447
Citations
2
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time neurochemical sensing of hydrogen peroxide production in brain tissue using advanced nanostructured Au microelectrodes functionalized with a ruthenium purple film

Rui M. Barbosa, Eliana Fernandes, Ana Ledo
2 citations
Electrochimica Acta
Electrochemical sensors and biosensors
0.42
article

Real-time neurochemical sensing of hydrogen peroxide production in brain tissue using advanced nanostructured Au microelectrodes functionalized with a ruthenium purple film

Rui M. Barbosa, Eliana Fernandes, Ana Ledo
article en
2 citations

Abstract

Real-time monitoring of H 2 O 2 is essential for understanding its role in neurological physio(path)ology. In this study, we developed an advanced electrochemical sensor utilizing nanostructured gold wire microelectrodes functionalized with a Ruthenium Purple (RP) film, a polynuclear transition metal hexacyanoferrate analog of the prototypical Prussian blue (PB). The RP film exhibits enhanced stability in neutral buffer solutions and reduced interference from biologically relevant cations such as Na + , Mg 2+ , and Ca 2+ . By integrating gold nanoparticles onto a nanoporous gold surface, we significantly increased the electroactive surface area of the microwire (ρ=26.1 ± 10.2). The electrodeposition of a thin RP film (4.23 ± 1.2 nm) resulted in a highly selective H 2 O 2 sensor, operating at an optimal potential of -0.05 V vs. Ag/AgCl, with a linear detection range of 0.5-500 µM, sensitivity of 1.18 ± 0.37 µA µM -1 cm -2 , and a low limit of detection (LOD) of 66.6 ± 34.9 nM. Adding a Nafion® layer enhanced the sensor's operational stability, maintaining optimal performance over three hours under physiological conditions of pH and ion concentration. We validated the sensor's capability to monitor transient changes in H 2 O 2 concentration in brain tissue by assessing its response to exogenously applied H 2 O 2 . Furthermore, we demonstrated that glutamate receptor activation in hippocampal slices induces a rapid and transient increase in extracellular H 2 O 2 levels, underscoring the sensor's potential for studying oxidative stress in neurobiological contexts.

Electrochimica ActaVol. 512
University of Coimbra (PT)
Programa Operacional Temático Factores de Competitividade, Fundação para a Ciência e a Tecnologia, European Regional Development Fund
Openalex Percentile: Top 36%
Electrochemical sensors and biosensors
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.