Novel autocalibration strategy for disposable potentiometric test strips

• New autocalibration procedure for disposable potentiometric test strips. • Application of the concept to the analysis of chloride for the diagnosis of cystic fibrosis. • Satisfactory results obtained with human sweat samples. • Concept as a basis for development of future test strips in a wide range of applications. Potentiometry, particularly involving ion-selective electrodes (ISEs), is widely employed in laboratories due to its selectivity and compatibility with portable instruments. However, ISEs face a drawback —instability over time, requiring frequent calibration for precise and reliable results. This manual calibration process contradicts the user-friendly concept and inhibits the development of single-use quantitative devices for untrained personnel. To solve this limitation, a novel potentiometric autocalibration procedure, which is automated, is presented, and successfully tested for the first time with versatile potentiometric disposable test strips to perform the determination of chloride ion in sweat as a demonstrator. The test strips are based on a cyclic olefin copolymer platform, where two identical Ag/AgCl chloride ISEs are integrated, one acting as indicator and the other as reference electrode. Comparison of chloride results in real sweat samples between those obtained with the proposed test strips performing the novel autocalibration procedure and using ion chromatography reveals that the automated procedure effectively allows quantitative chloride ion analysis with good analytical features: linear range from 10 to 150 mM (covering the pathological range), average inter-method error of 7 % and average RSD between test strips of 4 %. By carefully selecting the initial solution composition in direct contact with each electrode, the autocalibration ensures that potentiometric test strips can be calibrated just before its use without requiring conscious user involvement. This breakthrough not only streamlines the process but also opens the possibility for the development of cheap disposable potentiometric test strips, accessible to non-experts operators, to quantitatively determine selected analytes in different fields.

Authors

Institutions

Publication Details

Journal
Journal of Electroanalytical Chemistry
Published
2024-12-01
DOI
https://doi.org/10.1016/j.jelechem.2024.118829
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel autocalibration strategy for disposable potentiometric test strips

Mar Puyol, Antonio Calvo-López, J. Alonso, Laia Garrido-Carretero
2 citations
Journal of Electroanalytical Chemistry
Analytical Chemistry and Sensors
0.58
article

Novel autocalibration strategy for disposable potentiometric test strips

Mar Puyol, Antonio Calvo-López, J. Alonso, Laia Garrido-Carretero
article en
2 citations

Abstract

• New autocalibration procedure for disposable potentiometric test strips. • Application of the concept to the analysis of chloride for the diagnosis of cystic fibrosis. • Satisfactory results obtained with human sweat samples. • Concept as a basis for development of future test strips in a wide range of applications. Potentiometry, particularly involving ion-selective electrodes (ISEs), is widely employed in laboratories due to its selectivity and compatibility with portable instruments. However, ISEs face a drawback —instability over time, requiring frequent calibration for precise and reliable results. This manual calibration process contradicts the user-friendly concept and inhibits the development of single-use quantitative devices for untrained personnel. To solve this limitation, a novel potentiometric autocalibration procedure, which is automated, is presented, and successfully tested for the first time with versatile potentiometric disposable test strips to perform the determination of chloride ion in sweat as a demonstrator. The test strips are based on a cyclic olefin copolymer platform, where two identical Ag/AgCl chloride ISEs are integrated, one acting as indicator and the other as reference electrode. Comparison of chloride results in real sweat samples between those obtained with the proposed test strips performing the novel autocalibration procedure and using ion chromatography reveals that the automated procedure effectively allows quantitative chloride ion analysis with good analytical features: linear range from 10 to 150 mM (covering the pathological range), average inter-method error of 7 % and average RSD between test strips of 4 %. By carefully selecting the initial solution composition in direct contact with each electrode, the autocalibration ensures that potentiometric test strips can be calibrated just before its use without requiring conscious user involvement. This breakthrough not only streamlines the process but also opens the possibility for the development of cheap disposable potentiometric test strips, accessible to non-experts operators, to quantitatively determine selected analytes in different fields.

Journal of Electroanalytical ChemistryVol. 977
Universitat Autònoma de Barcelona (ES)
Ministerio de Ciencia e Innovación
Openalex Percentile: Top 35%
Analytical Chemistry and Sensors
0.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.