Application of semi-quantitative loop-mediated isothermal amplification for gene expression study in Expi293 cells

BACKGROUND: Mammalian cell cultures play a key role in the pharmaceutical industry, requiring constant monitoring of the cell conditions during fermentation. In addition to monitoring of the physical-chemical parameters, it is important to evaluate the transcription state of cells, for which gene expression analysis is used. Currently, quantitative reverse transcription polymerase chain reaction (qPCR) is the dominant method. However, the loop-mediated isothermal amplification (LAMP) technique also attracts attention due to its high specificity, sensitivity and reaction rate. LAMP is becoming a promising tool for rapid analysis of gene expression, especially under the conditions of limited biological material or a large volume of samples. AIM: Development of a technique for semi-quantifying the expression level of target genes in human cell culture Expi293 using LAMP. MATERIALS AND METHODS: For LAMP, a recombinant large fragment of Bacillus stearothermophilus DNA polymerase (Bst-pol) was obtained, purified, and optimal reaction conditions were determined. SYBR Green I and LUCS13 were used as intercalating dyes. The amplification parameters for different concentrations of the enzyme and the dye were analyzed. Standard SYBR Green I kits were used for qPCR. Both methods were compared when analyzing the expression of IGF1, FGF2 and EIF3i genes in cell lines with an increased expression level of these genes. RESULTS: It has been shown that using LUCS13 dye provides the classic S-shape of the signal accumulation curve in LAMP, while using SYBR Green I dye causes artifacts. The optimal concentration of Bst-pol was 40 ng/µl. When comparing the two methods, it was found that LAMP has greater sensitivity, allows determining gene expression with an accuracy comparable to qPCR, demonstrating a shorter reaction time (up to 35 minutes). CONCLUSION: Although qPCR remains the main method for assessing the level of gene expression, LAMP offers a number of advantages that make it an attractive alternative for various biotechnological purposes. Due to its high speed, ease of execution and accessibility, as well as high sensitivity and specificity, LAMP is a valuable technique for rapid analysis of gene expression during cell culture monitoring.

Authors

Institutions

Publication Details

Journal
Genes and Cells
Published
2024-12-01
DOI
https://doi.org/10.17816/gc635661
Citations
1
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of semi-quantitative loop-mediated isothermal amplification for gene expression study in Expi293 cells

Gleb Y. Fisunov, В. Н. Лазарев, Daria Kharlampieva, Ekaterina Grafskaia et al.
1 citations
Genes and Cells
Biosensors and Analytical Detection
0.18
article

Application of semi-quantitative loop-mediated isothermal amplification for gene expression study in Expi293 cells

Gleb Y. Fisunov, В. Н. Лазарев, Daria Kharlampieva, Ekaterina Grafskaia, Valentin A. Manuvera, Pavel A. Bobrovsky
article en
1 citations

Abstract

BACKGROUND: Mammalian cell cultures play a key role in the pharmaceutical industry, requiring constant monitoring of the cell conditions during fermentation. In addition to monitoring of the physical-chemical parameters, it is important to evaluate the transcription state of cells, for which gene expression analysis is used. Currently, quantitative reverse transcription polymerase chain reaction (qPCR) is the dominant method. However, the loop-mediated isothermal amplification (LAMP) technique also attracts attention due to its high specificity, sensitivity and reaction rate. LAMP is becoming a promising tool for rapid analysis of gene expression, especially under the conditions of limited biological material or a large volume of samples. AIM: Development of a technique for semi-quantifying the expression level of target genes in human cell culture Expi293 using LAMP. MATERIALS AND METHODS: For LAMP, a recombinant large fragment of Bacillus stearothermophilus DNA polymerase (Bst-pol) was obtained, purified, and optimal reaction conditions were determined. SYBR Green I and LUCS13 were used as intercalating dyes. The amplification parameters for different concentrations of the enzyme and the dye were analyzed. Standard SYBR Green I kits were used for qPCR. Both methods were compared when analyzing the expression of IGF1, FGF2 and EIF3i genes in cell lines with an increased expression level of these genes. RESULTS: It has been shown that using LUCS13 dye provides the classic S-shape of the signal accumulation curve in LAMP, while using SYBR Green I dye causes artifacts. The optimal concentration of Bst-pol was 40 ng/µl. When comparing the two methods, it was found that LAMP has greater sensitivity, allows determining gene expression with an accuracy comparable to qPCR, demonstrating a shorter reaction time (up to 35 minutes). CONCLUSION: Although qPCR remains the main method for assessing the level of gene expression, LAMP offers a number of advantages that make it an attractive alternative for various biotechnological purposes. Due to its high speed, ease of execution and accessibility, as well as high sensitivity and specificity, LAMP is a valuable technique for rapid analysis of gene expression during cell culture monitoring.

Genes and CellsVol. 19(4)
Moscow Institute of Physics and Technology (RU), Institute for Systems Biology (US), InSysBio (Russia) (RU), Federal Medical-Biological Agency (RU)
Industry, innovation and infrastructure
Openalex Percentile: Top 50%
Biosensors and Analytical Detection
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.