ANALISIS NILAI COMPUTED TOMOGRAPHY DOSE INDEX (CTDI) PADA PHANTOM KEPALA DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH SAYANG RAKYAT MAKASSAR

This research aims to determine the CTDI value on a CT Scan aircraft using Dose Profiler and to determine the comparison of the CTDI (Computed Tomography Dose Index) value on the surface of each measurement position. The measurement method was carried out by measuring the CT Scan radiation dose with the CTDI value on the phantom using a RaySafe multimeter at a voltage of 130 kV, using a thickness of 10 mm, a time current accuracy of 100 mAs, 200 mAs and 300 mAs. The research results show the dose received on the surface of each type of phantom position with different time current accuracy respectively for a time current of 100 mAs at the center (9.139 mGy), type 1 (9.606 mGy), type 2 (9.170) type 3 (9.221) , and type 4 (9,210). A time current of 200 mAs is found at the center (9,110 mGy), edge 1 (9,578 mGy), edge 2 (9,546 mGy), edge 3 (9,224 mGy), and edge 4 (9,200 mGy). A time current of 300 mAs is found at the center position (18.39 mGy), edge 1 (19.33 mGy), edge 2 (19.18 mGy), edge 3 (18.48 mGy), and 4 (18.51 mGy) . Time-current variations affect the radiation dose that can be received by the phantom and have a linear influence on the CTDIvol value.

Authors

Institutions

Publication Details

Journal
JOURNAL ONLINE OF PHYSICS
Published
2024-11-08
DOI
https://doi.org/10.22437/jop.v10i1.37149
Primary Topic
Management and Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALISIS NILAI COMPUTED TOMOGRAPHY DOSE INDEX (CTDI) PADA PHANTOM KEPALA DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH SAYANG RAKYAT MAKASSAR

Sri Zelviani, Jumardin Jumardin, Khaerul Bariah, Ilham Ilham
JOURNAL ONLINE OF PHYSICS
Management and Optimization Techniques
article

ANALISIS NILAI COMPUTED TOMOGRAPHY DOSE INDEX (CTDI) PADA PHANTOM KEPALA DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH SAYANG RAKYAT MAKASSAR

Sri Zelviani, Jumardin Jumardin, Khaerul Bariah, Ilham Ilham
article en

Abstract

This research aims to determine the CTDI value on a CT Scan aircraft using Dose Profiler and to determine the comparison of the CTDI (Computed Tomography Dose Index) value on the surface of each measurement position. The measurement method was carried out by measuring the CT Scan radiation dose with the CTDI value on the phantom using a RaySafe multimeter at a voltage of 130 kV, using a thickness of 10 mm, a time current accuracy of 100 mAs, 200 mAs and 300 mAs. The research results show the dose received on the surface of each type of phantom position with different time current accuracy respectively for a time current of 100 mAs at the center (9.139 mGy), type 1 (9.606 mGy), type 2 (9.170) type 3 (9.221) , and type 4 (9,210). A time current of 200 mAs is found at the center (9,110 mGy), edge 1 (9,578 mGy), edge 2 (9,546 mGy), edge 3 (9,224 mGy), and edge 4 (9,200 mGy). A time current of 300 mAs is found at the center position (18.39 mGy), edge 1 (19.33 mGy), edge 2 (19.18 mGy), edge 3 (18.48 mGy), and 4 (18.51 mGy) . Time-current variations affect the radiation dose that can be received by the phantom and have a linear influence on the CTDIvol value.

JOURNAL ONLINE OF PHYSICSVol. 10(1)
Islamic University (BD), Universitas Islam Makassar (ID)
Good health and well-being
Openalex Percentile: Top 63%
Management and Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ANALISIS NILAI COMPUTED TOMOGRAPHY DOSE INDEX (CTDI) PADA PHANTOM KEPALA DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM DAERAH SAYANG RAKYAT MAKASSAR — Sri Zelviani, Jumardin Jumardin, et al. · JOURNAL ONLINE OF PHYSICS (2024) | TGRS Research Map | TGRS