Effect of dental implant neck profile switching on crestal bone healing

Introduction: The majority of dental implants and prostheses rely on the association with the soft tissues that may be vulnerable to future requirements. There are two main requirements for osseointegration: first, the bone must be healthy; second, the implant must be stable and able to withstand the functional load. Methods and Results: Using both the computer12 model and finite element analysis technique to assess the bone space volume in implants with narrow-neck hybrid design compared with butt platform and bevel design at an inter-implant distance of 1 mm, the result showed approximately 56.7 mm in the butt joint platform design implant and between two bevel platforms (+2.74% or more), while it showed 78.42 mm (+38.32%) between two narrow-neck hybrid designs. Discussion and Conclusion: The implant platform switching technique is used to decrease the stress on the crestal bone and allow for better load distribution. This can be done at two levels: one is at the fixture–abutment interface, and the second within the bone at the fixture itself in the body–neck area. The narrow-neck hybrid design seems to be superior in lowering the stress on crestal bone and to provide more room for bone healing potential with less negative effect on soft tissue healing.

Authors

Publication Details

Journal
Journal of emergency medicine, trauma & acute care
Published
2024-11-28
DOI
https://doi.org/10.5339/jemtac.2024.absc.6
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of dental implant neck profile switching on crestal bone healing

Mudher MB. Alsunbuli
Journal of emergency medicine, trauma & acute care
Dental Implant Techniques and Outcomes
article

Effect of dental implant neck profile switching on crestal bone healing

Mudher MB. Alsunbuli
article en

Abstract

Introduction: The majority of dental implants and prostheses rely on the association with the soft tissues that may be vulnerable to future requirements. There are two main requirements for osseointegration: first, the bone must be healthy; second, the implant must be stable and able to withstand the functional load. Methods and Results: Using both the computer12 model and finite element analysis technique to assess the bone space volume in implants with narrow-neck hybrid design compared with butt platform and bevel design at an inter-implant distance of 1 mm, the result showed approximately 56.7 mm in the butt joint platform design implant and between two bevel platforms (+2.74% or more), while it showed 78.42 mm (+38.32%) between two narrow-neck hybrid designs. Discussion and Conclusion: The implant platform switching technique is used to decrease the stress on the crestal bone and allow for better load distribution. This can be done at two levels: one is at the fixture–abutment interface, and the second within the bone at the fixture itself in the body–neck area. The narrow-neck hybrid design seems to be superior in lowering the stress on crestal bone and to provide more room for bone healing potential with less negative effect on soft tissue healing.

Journal of emergency medicine, trauma & acute careVol. 2024(6)
Openalex Percentile: Top 67%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of dental implant neck profile switching on crestal bone healing — Mudher MB. Alsunbuli · Journal of emergency medicine, trauma & acute care (2024) | TGRS Research Map | TGRS